Vötsch Temperature Test Chamber VT 6080 -60°C / +160°C 800 Liter Test Space EX-Protected


Item ID: 21801

Condition: Used

Stock: Only ${ $store.getters['21801/currentItemVariation'].stock.net } in stock

The item is already sold

* Excl. VAT excl. Shipping

Vötsch Temperature Test Chamber


Here we offer a Heraeus Vötsch temperature chamber.

Water-cooled
Test chamber Ex-protected
Test chamber volume 800 liters
Test chamber dimensions approx.: Width 1060 mm Depth 800 mm Height 920 mm
External dimensions approx.: Width 1390 mm Depth 1870 mm Height 2956 mm
Temperature range -60°C to +160°C
Temperature deviation over time ±0.3 to ±0.8 K
Temperature deviation spatially ±0.5 to ±0.2 K
Temperature change rate cooling 1.8 K/min
Temperature change rate heating 2.5 K/min
Refrigerant: R-404 A
Voltage 3/N/PE AC 400V±10% 50Hz
Rated power 11 kW
Rated current 25 A
Type: VT 6080
For you as a buyer, the following information for safety!
 
The following points will be carried out on our offered chambers in advance:
1. Function check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will undergo a test run monitored with calibrated devices.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data, specifications are reserved!)
 
We would be happy to answer any further questions by phone.

Technical characteristic Value
Item ID 21801
Condition Used
Model Vötsch Temperaturprüfschrank VT 6080
Manufacturer Vötsch
Weight 400000 g
document.querySelector("form > input[data-mail='subject']").value = "Webshop - Frage zu Artikel - Artikel-ID: " + vueApp.$store.state.items[21801].variation.documents[0].data.item.id;

EU Responsible Person

Weiss Technik GmbH
Greizer Straße 41-49
35447 Reiskirchen Germany
info@weiss-technik.com
+49 6408 84-0

Manufacturer details

Vötsch
Weiss Technik GmbH
Germany

Switch to environmentally friendly refrigerant

The following work can be performed on climate chambers. Please contact us if you are interested.

 

  • Extraction and proper disposal of the previous refrigerant
  • Replacement of necessary components, if unavoidable
  • Evacuate the circuit and refill it with R 452A, for example.
  • Checking / adjusting overheating in expansion valves
  • Leak test
  • Test run of the system