CTS Temperature Testing Chamber (Conditioning Device for External Test Rooms) -40°C to +180°C 1000 l TSR-30/1000


Item ID: 23988

Condition: Used

Stock: Only ${ $store.getters['23988/currentItemVariation'].stock.net } in stock

EUR 28,500.00 *
Content 1 piece
Unit price EUR 28,500.00 / piece
The item is in stock

PAYMENT METHODS:

²


* Excl. VAT excl. Shipping

CTS


Type: TSR-30/1000

Water-cooled
The type designation of the CTS cabinet series is composed as follows:
e.g. Type TSR -30/1000
1) T means: Temperature
2) S means: Stress-Screening
3) R means: external conditioning
4) -30 means: lower temperature -30 °C
5) 1000 means: 1000 liters test chamber volume
Technical performance data:
A) TSR-30/1000 base unit without hose connections,
i.e. when used as a standalone temperature test chamber
Temperature tests:
Temperature range -40°C to +180°C
End temperature -45°C
Temperature deviation ≤ ±0.3 K over time
Temperature change rate according to IEC 60068-3-5
Heating 6.0 K/min
Cooling 5.0 K/min
Heat radiation
approx. 5000 W at +20°C
approx. 4200 W at ± 0°C
approx. 3000 W at -20°C
The technical data refer to an ambient temperature of +25 °C,
nominal voltage 400V, without test specimen, without radiation and without additional devices.

Air flow rate
approx. 2000m³/h
B) TSR-30/1000 base unit with hose connections,
for connection to a site-specific external test chamber
Temperature tests:
Temperature range -30°C to +170°C
Temperature deviation ≤ ±0.1 to 0.5 K over time
Temperature change rate on average,
measured with a short-circuited circuit
Heating 4.0 K/min
Cooling 4.0 K/min
in the range of +150°C to -10°C
The technical data refer to an ambient temperature of +25 °C,
nominal voltage 400V, without test specimen, without radiation and without additional devices,
measured with a short-circuited circuit
Caution: The site-specific external test chamber must be absolutely airtight and properly insulated,
any penetrations must be optimally sealed on site.
Dimensions:
Test volume 1000 liters
Recirculation connection Ø 200 mm
Test chamber dimensions Height 900 mm Width 1000 mm Depth 1100 mm
External dimensions Height 1950 mm Width 1270 mm Depth 2245 mm
Technical design:
Cooling unit:
water-cooled, low noise full hermetic
infinitely variable power adjustment through
electronic monitoring and control system,
environmentally friendly refrigerant R404A
Door:
fully opening door, door hinge on the left,
one-hand operation, lockable.
Insert rack:
Stainless steel, support area 970 x 980mm
Load per rack max. 35 kg
Total load at max. rack loading 100 kg
Test chamber lighting: Halogen lamp 20 W, 12 V
Control:
- 32 Bit - Controller
- LCD control panel
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Nominal power 13.3 kW
Protection class IP 22
Sound pressure level < 60 dB(A)
Weight approx. 850 kg
For your safety as a buyer, the following information!
The following points will be carried out in advance on our offered chambers:
1. Function check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are reserved!)
Further questions can be answered by phone.

Technical characteristic Value
Item ID 23988
Condition Used
Model CTS Temperaturprüfschrank
Manufacturer CTS
Weight 850000 g
document.querySelector("form > input[data-mail='subject']").value = "Webshop - Frage zu Artikel - Artikel-ID: " + vueApp.$store.state.items[23988].variation.documents[0].data.item.id;

EU Responsible Person

CTS Clima Temperatur Systeme GmbH
Lotzenäcker 21
72379 Hechingen Germany
info@cts-umweltsimulation.de
+49 7471 - 98 50 - 0

Manufacturer details

CTS
CTS Clima Temperatur Systeme GmbH
Germany

Switch to environmentally friendly refrigerant

The following work can be performed on climate chambers. Please contact us if you are interested.

 

  • Extraction and proper disposal of the previous refrigerant
  • Replacement of necessary components, if unavoidable
  • Evacuate the circuit and refill it with R 452A, for example.
  • Checking / adjusting overheating in expansion valves
  • Leak test
  • Test run of the system