Weiss Temperature Chamber Cold-Heat Test Chamber DU11/300/80 -75° to +180°C


Item ID: 14329

Condition: Used

Stock: Only ${ $store.getters['14329/currentItemVariation'].stock.net } in stock

The item is already sold

* Excl. VAT excl. Shipping

Weiss Umwelttechnik


Here we offer you a temperature chamber.
Test chamber volume: 300 liters
External dimensions
Height 1700 mm Width 800 mm Depth 1620 mm
Maximum load of the test chamber floor: 35 kg
Maximum load per shelf: 35 kg
Total load: 150 kg
Nominal voltage: 400V/3Ph + N + PE/ 50 Hz (+6%/-10%)
Connection voltage: 4.9 kVA
Max. heat output to the environment: 4.2 kW
Temperature range: -75 to +180 °C
Temperature stability: ±0.2 - ±0.5 K
Temperature change rate
Heating: 3.0 K / min
Cooling: 1.8 K / min
Control Prodicon PLUS
Type: DU11/300/80
Condition: used
Scope of delivery: (Weiss DU11/300/80)
The device has been tested on-site and is fully functional.
 
If you have any further questions, we would be happy to answer them by phone.
Written orders possible via email or fax

Technical characteristic Value
Item ID 14329
Condition Used
Model DU11/300/80
Manufacturer Weiss
Weight 480000 g
document.querySelector("form > input[data-mail='subject']").value = "Webshop - Frage zu Artikel - Artikel-ID: " + vueApp.$store.state.items[14329].variation.documents[0].data.item.id;

EU Responsible Person

Weiss Technik GmbH
Greizer Straße 41-49
35447 Reiskirchen Germany
info@weiss-technik.com
+49 6408 84-0

Manufacturer details

Weiss
Weiss Technik GmbH
Germany

Switch to environmentally friendly refrigerant

The following work can be performed on climate chambers. Please contact us if you are interested.

 

  • Extraction and proper disposal of the previous refrigerant
  • Replacement of necessary components, if unavoidable
  • Evacuate the circuit and refill it with R 452A, for example.
  • Checking / adjusting overheating in expansion valves
  • Leak test
  • Test run of the system

Climate test cabinets

Show all