Weiss Cold-Heat Test Chamber and Climate Test Chamber SB1/300/40


Item ID: 18002

Condition: Used

Stock: Only ${ $store.getters['18002/currentItemVariation'].stock.net } in stock

PAYMENT METHODS:

²

if(!document.getElementById('paypal-smart-payment-script')) { var script = document.createElement("script"); script.type = "module"; script.id = "paypal-smart-payment-script"; script.src = "https://cdn02.plentyone.com/7ukspn3affoc/plugin/23/paypal/js/smartPaymentScript.min.js"; script.setAttribute("data-client-id", "AfslQana4f4CQjHvRBnUc6vBJg5jgJuZFwM-SbrTiGKUAqB7MrxQv3QWFdQ6U1h7ogMDokT1DNBzRxMw"); script.setAttribute("data-user-id-token", ""); script.setAttribute("data-merchant-id", "HAR2LLRJHKH66"); script.setAttribute("data-currency", "EUR"); script.setAttribute("data-append-trailing-slash", ""); script.setAttribute("data-locale", "en_GB"); script.setAttribute("sandbox", ""); script.setAttribute("googlePayComponent", 0); script.setAttribute("applePayComponent", 0); script.setAttribute("logToken", "dfec39b6f6b40065c8f05ef7f3e64756"); document.body.appendChild(script); } else { var script = document.getElementById('paypal-smart-payment-script'); script.src = "https://cdn02.plentyone.com/7ukspn3affoc/plugin/23/paypal/js/smartPaymentScript.min.js"; script.setAttribute("data-client-id", "AfslQana4f4CQjHvRBnUc6vBJg5jgJuZFwM-SbrTiGKUAqB7MrxQv3QWFdQ6U1h7ogMDokT1DNBzRxMw"); script.setAttribute("data-user-id-token", ""); script.setAttribute("data-merchant-id", "HAR2LLRJHKH66"); script.setAttribute("data-currency", "EUR"); script.setAttribute("data-append-trailing-slash", ""); script.setAttribute("data-locale", "en_GB"); script.setAttribute("sandbox", ""); script.setAttribute("googlePayComponent", 0); script.setAttribute("applePayComponent", 0); script.setAttribute("logToken", "dfec39b6f6b40065c8f05ef7f3e64756"); }
if (typeof paypal_plenty_sdk === 'undefined' || typeof renderPayPalButtons !== 'function') { document.addEventListener('payPalScriptInitialized', () => { renderPayPalButtons('6b0022569353b', 'paypal', 'buynow', 'rect', 'gold'); }); } else { renderPayPalButtons('6b0022569353b', 'paypal', 'buynow', 'rect', 'gold'); }
if(!document.getElementById('paypal-smart-payment-script')) { var script = document.createElement("script"); script.type = "module"; script.id = "paypal-smart-payment-script"; script.src = "https://cdn02.plentyone.com/7ukspn3affoc/plugin/23/paypal/js/smartPaymentScript.min.js"; script.setAttribute("data-client-id", "AfslQana4f4CQjHvRBnUc6vBJg5jgJuZFwM-SbrTiGKUAqB7MrxQv3QWFdQ6U1h7ogMDokT1DNBzRxMw"); script.setAttribute("data-user-id-token", ""); script.setAttribute("data-merchant-id", "HAR2LLRJHKH66"); script.setAttribute("data-currency", "EUR"); script.setAttribute("data-append-trailing-slash", ""); script.setAttribute("data-locale", "en_GB"); script.setAttribute("sandbox", ""); script.setAttribute("googlePayComponent", 0); script.setAttribute("applePayComponent", 0); script.setAttribute("logToken", "dfec39b6f6b40065c8f05ef7f3e64756"); document.body.appendChild(script); } else { var script = document.getElementById('paypal-smart-payment-script'); script.src = "https://cdn02.plentyone.com/7ukspn3affoc/plugin/23/paypal/js/smartPaymentScript.min.js"; script.setAttribute("data-client-id", "AfslQana4f4CQjHvRBnUc6vBJg5jgJuZFwM-SbrTiGKUAqB7MrxQv3QWFdQ6U1h7ogMDokT1DNBzRxMw"); script.setAttribute("data-user-id-token", ""); script.setAttribute("data-merchant-id", "HAR2LLRJHKH66"); script.setAttribute("data-currency", "EUR"); script.setAttribute("data-append-trailing-slash", ""); script.setAttribute("data-locale", "en_GB"); script.setAttribute("sandbox", ""); script.setAttribute("googlePayComponent", 0); script.setAttribute("applePayComponent", 0); script.setAttribute("logToken", "dfec39b6f6b40065c8f05ef7f3e64756"); }

* Excl. VAT excl. Shipping

Weiss Cold-Heat Test Chamber and Climate Test Chamber


Here we offer a Weiss Cold-Heat Test Chamber and Climate Test Chamber.
Weiss Cold-Heat Test Chamber and Climate Test Chamber
SB1 300/40
Installation dimensions: H 1800 mm W 1100 D 2000
External dimensions: H 1700 mm W 800 mm D 1620 mm
Weight: 360 kg
Power connection: 4.8 kVA
Plug: CEE 16 A
Heat output to the installation room: 1.8 kW average Max. 3.3 kW
Sound pressure level: 58 dB(A)
Connection voltage: 400V/3Ph + N + PE/ 50 Hz (+6%/-10%)
Condensate drain - 3/4" hose nozzle,
Drain valve - 1/2" hose nozzle,
Water tank connection - external thread, 3/8"
Temperature range: Cold-Heat operation -40...+180 °C
Temperature range: Climate operation +10...+95 °C
Humidity range: 10...98 % r. H.
Temperature change rate: Cooling 3.1 approx. K/min
Temperature change rate: Heating 3.0 approx. K/min
The temporal temperature stability in climate operation is ±0.1...±0.5 K.
The temporal temperature stability in cold-heat operation (without climate) is ±0.2...±0.5 K.
The temporal humidity stability in the entire working range is ±2...±3 %r.H.
max total load: 150 kg
max load test chamber floor: 35 kg
max load insert rack: 35 kg
Type: SB1/300/40
For you as a buyer, the following information for safety!
 
The following points will be carried out in advance on our offered chambers:
Function check and replacement of necessary components
New filling with legally compliant refrigerant
Tightness test with certificate
After successful inspection, the chambers will undergo a test run monitored with calibrated devices.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are reserved!)
 
We can gladly answer further questions by phone.
Written orders possible via email or fax
 

document.querySelector("form > input[data-mail='subject']").value = "Webshop - Frage zu Artikel - Artikel-ID: " + vueApp.$store.state.items[18002].variation.documents[0].data.item.id;

Switch to environmentally friendly refrigerant

The following work can be performed on climate chambers. Please contact us if you are interested.

 

  • Extraction and proper disposal of the previous refrigerant
  • Replacement of necessary components, if unavoidable
  • Evacuate the circuit and refill it with R 452A, for example.
  • Checking / adjusting overheating in expansion valves
  • Leak test
  • Test run of the system