Weiss climate testing chamber WK-1500/70/5/S with additional operation for UV irradiation


Item ID: 7244

Condition: Used

Stock: Only ${ $store.getters['7244/currentItemVariation'].stock.net } in stock

The item is already sold

* Excl. VAT excl. Shipping

Weiss Climate Test Chamber WK-1500/70/5/S


Here we offer a Weiss Climate Test Chamber WK-1500/70/5/S with additional operation for UV irradiation.
Weiss Temperature and Climate Test Chamber WK-1500/70/5/S
Test chamber volume: approx. 1540 liters
Test chamber dimensions:
Height mm    950
Width mm   1100
Depth mm    1475
External dimensions:   
Height mm    2005
Width mm   1300
Depth mm    2450
Cooling water data:
Required water pressure   2.5 to 6 bar
Pressure difference in the cooling water circuit   > 2 bar
Inlet temperature   12 °C to 28 °C
pH value   7.5 to 9
Quality   free of impurities, as colorless and clear as possible (max. size of dirt particles 100)
Total hardness   max. 8°dH (approx. 80 mg CaO/1)
Electrical conductivity   < 500 µS/cm (reference temperature 20 °C)
Chloride   < 10 g/m3
Sulfate   < 100 g/m3
Bicarbonate   < 300 g/m3
Ratio of sulfate / bicarbonate   < 1
Operating data:
Test chamber lighting   Halogen bulb 24V, 50W
Nominal voltage     3/N / PE AC 400 V + 10% 50 Hz or 3/N / PE AC 440 V ± 10% 60 Hz
Nominal power    27 kW
Nominal current   38 A
Fuse on site    63 A slow
Protection class of control cabinet and operating panel   IP 54
Heat output of water-cooled test chambers
max. heat output to the environment    2.5 kW
Sound pressure level approx.
measured at 1m distance from the front. 1m height and free field measurement    73 dB(A)
Data for temperature tests:
Temperature range: -70 to +180 °C
Temperature deviation over time in the center of the usable space   ± 0.1 to ± 0.5 K
Spatial temperature deviation   ± 0.5 to ± 2 K
Temperature gradient
(according to IEC 60068-3-5)   1 to 4 K
Rate of temperature change (according to IEC 60068-3-5)
Heating   6 K/min
Cooling   5 K/min
Heat compensation at +20 °C at -20 °C   5000 W/ 5000 W
Data for climate tests:
Data for humidification system
Volume of the storage tank   20 I
Water quality   demineralized
pH value   6 to 7
Conductivity   5 to 20 pS/cm3
Water consumption
at constant +40 °C, 92 % r.H.   21/24 h
Temperature range   +10 to +95 °C
Humidity range   10 to 98 % r.H.
Temperature deviation over time in the center of the usable space   ± 0.1 to ± 0.3 K
Spatial temperature deviation   ± 0.5 to ± 1 K
Temperature gradient
(according to IEC 60068-3-5)   1 to 2 K
Humidity fluctuation over time in the center of the usable space   1 to 13 % r.H.
Heat compensation
in the range of +25 °C to +95 °C at a relative humidity of up to 90%   500 W
Irradiation unit:
The irradiation unit contains 16 UV tubes and is built on a pull-out
insert (1). This is pushed onto the insert rack (2) in the test chamber. The
rack for the irradiation unit should not be moved from its position. For the
test specimens, another rack (3) is available, which can be pushed to the desired height in the
test chamber.
Refrigerant: R404 A/ R 23
Weight: 995 kg
Type: WK-1500/70/5/S
Condition: used
Scope of delivery: (See image)
2 weeks commissioning guarantee
We deliver with express shipping (DHL, UPS, TNT)
 
Further questions can be answered by phone.
Written orders possible via email or fax

Technical characteristic Value
Item ID 7244
Condition Used
Model WK-1500/70/5/S
Manufacturer Weiss
Weight 995000 g
document.querySelector("form > input[data-mail='subject']").value = "Webshop - Frage zu Artikel - Artikel-ID: " + vueApp.$store.state.items[7244].variation.documents[0].data.item.id;

EU Responsible Person

Weiss Technik GmbH
Greizer Straße 41-49
35447 Reiskirchen Germany
info@weiss-technik.com
+49 6408 84-0

Manufacturer details

Weiss
Weiss Technik GmbH
Germany

Switch to environmentally friendly refrigerant

The following work can be performed on climate chambers. Please contact us if you are interested.

 

  • Extraction and proper disposal of the previous refrigerant
  • Replacement of necessary components, if unavoidable
  • Evacuate the circuit and refill it with R 452A, for example.
  • Checking / adjusting overheating in expansion valves
  • Leak test
  • Test run of the system