Vötsch Emission Testing Chamber


Here we offer you an emission testing chamber.

Water-cooled
Test chamber volume 1000 liters (usable) (916) liters Setting container 480 liters
Specifications for temperature tests:
Temperature range +20°C to +130°C
Temperature deviation over time K ±0.1 to ±0.3
Temperature deviation spatially K ±0.1 to K ±0.5
Temperature gradient K 1
Rate of temperature change:
Cooling K/min 0.3
Heating K/min 0.4
Specifications for climate tests:
Temperature range +20°C to +130°C
Humidity range 5 to 95%
Dew point range +5°C to +60°C
Humidity deviation over time % 1 to 3
Data for carrier gas:
Carrier gas on customer side: Dry, cleaned, emission-free compressed air/nitrogen
Permissible pressure range: 4 - 8 bar g
Max. pressure dew point at 6 bar g: -5°C
Max. consumption (during desorption): 4.5 m³/h
Carrier gas exchange rate 0.1 to 2.1 chamber volumes per hour.

Performance range for desorption
Desorption temperature up to max. +240°C, adjustable
Test chamber surface temperature between +220°C and +240°C
Air/carrier gas consumption < 4 m³/h
Test chamber dimensions: Width 750 mm Depth 1630 mm Height 750 mm
Test chamber door 670 x 670 mm
External dimensions: Width 1350 mm Height 2157 mm Depth 2940 mm
Rated current 17 A
Rated power 9.0 kW
Electrical connection 3/N/PE AC 400V ± 10% 50Hz
ekom oil-free compressor of the series DK50 2VS
2-cylinder unit
25-liter pressure vessel
Operating pressure: max. 8 bar
Delivery capacity: 134 L/min
Weight 1200 kg
For you as a buyer, the following information for your safety!
 
The following points will be carried out on our offered chambers in advance:
1. Function check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. After successful inspection, the chambers will undergo a test run monitored with calibrated devices.
Type: VCE 1000 classic
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data, specifications are reserved!)
Further questions can be answered by phone.

document.querySelector("form > input[data-mail='subject']").value = "Webshop - Frage zu Artikel - Artikel-ID: " + vueApp.$store.state.items[23386].variation.documents[0].data.item.id;

Switch to environmentally friendly refrigerant

The following work can be performed on climate chambers. Please contact us if you are interested.

 

  • Extraction and proper disposal of the previous refrigerant
  • Replacement of necessary components, if unavoidable
  • Evacuate the circuit and refill it with R 452A, for example.
  • Checking / adjusting overheating in expansion valves
  • Leak test
  • Test run of the system