Vötsch Table Test Chamber for Temperature Tests -40°C to +180°C VT 4004


Item ID: 23780

Condition: Used

Stock: Only ${ $store.getters['23780/currentItemVariation'].stock.net } in stock

The item is already sold

* Excl. VAT excl. Shipping

Vötsch Table Test Chamber


Here we offer you a Vötsch Table Test Chamber.
Vötsch Table Test Chamber Air-Cooled 35 Liters
External dimensions: Width: 950 mm Height: 630 mm Depth: 830 mm
Internal dimensions: Width: 320 mm Height: 400 mm Depth: 270 mm
Key values for temperature tests:
Temperature range: -40°C to +180°C
Temporal temperature deviation ± 1.0 K
Spatial temperature deviation ± 2.0 K
Heating rate 5 K/min
Cooling rate 5 K/min
Heat compensation max. 500 W
Interface: RS232
Refrigerant R404A
Voltage: 230V ±6/10% 1/N 50Hz
Rated power 1.5 W Rated current 7.5 A
Weight: approx. 130 kg
Type: VT 4004
For you as a buyer, the following information for your safety!
 
The following points will be carried out on our offered chambers in advance:
1. Function check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are reserved!)
We are happy to answer any further questions by phone.

Technical characteristic Value
Item ID 23780
Condition Used
Model Vötsch Tisch-Prüfschrank
Manufacturer Vötsch
Weight 60000 g
document.querySelector("form > input[data-mail='subject']").value = "Webshop - Frage zu Artikel - Artikel-ID: " + vueApp.$store.state.items[23780].variation.documents[0].data.item.id;

EU Responsible Person

Weiss Technik GmbH
Greizer Straße 41-49
35447 Reiskirchen Germany
info@weiss-technik.com
+49 6408 84-0

Manufacturer details

Vötsch
Weiss Technik GmbH
Germany

Switch to environmentally friendly refrigerant

The following work can be performed on climate chambers. Please contact us if you are interested.

 

  • Extraction and proper disposal of the previous refrigerant
  • Replacement of necessary components, if unavoidable
  • Evacuate the circuit and refill it with R 452A, for example.
  • Checking / adjusting overheating in expansion valves
  • Leak test
  • Test run of the system