Vötsch Shock Test Chamber +50°C to +220°C -75°C to +70°C VT 7012 S2
Item ID: 24928
Condition: Used
Stock: Only ${ $store.getters['24928/currentItemVariation'].stock.net } in stock
PAYMENT METHODS:
²
* Excl. VAT excl. Shipping
Vötsch
Type: VT 7012 S2
Water-cooled
Two-chamber design
Warm chamber:
The temperature range of the warm chamber is from +50°C to +220°C
Temporal temperature deviation in the center of the usable space ± 1 K
Spatial temperature deviation ± 2 K
Temperature change rate
Heating 11 K/min
Cold chamber:
the cold chamber from -74.5°C to +70°C
Temporal temperature deviation in the center of the usable space ± 1 K
Spatial temperature deviation ± 2 K
Temperature change rate
Heating 2 K/min
Cooling 3 K/min
Test chamber volume 125 liters
Temperature range warm chamber +50°C to +220°C
Temperature range cold chamber -80°C to +70°C
Test chamber dimensions Width 470mm Depth 650mm Height 410mm
External dimensions Width 930mm Depth 2115mm Height 1970+mm
Pass-through ∅ 67mm
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Rated power 10 kW
Rated current 25 A
Refrigerant R-452A / R-23
Weight: 1000 kg
For your safety as a buyer, the following information!
The following points will be carried out on our offered chambers in advance:
1. Function check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are reserved!)
We would be happy to answer any further questions by phone.
Switch to environmentally friendly refrigerant
The following work can be performed on climate chambers. Please contact us if you are interested.
- Extraction and proper disposal of the previous refrigerant
- Replacement of necessary components, if unavoidable
- Evacuate the circuit and refill it with R 452A, for example.
- Checking / adjusting overheating in expansion valves
- Leak test
- Test run of the system