Vötsch Climate Test Chamber with Humidity -70 to +180°C 100 Liters VCL 7010


Item ID: 24072

Condition: Used

Stock: Only ${ $store.getters['24072/currentItemVariation'].stock.net } in stock

PAYMENT METHODS:

²

if(!document.getElementById('paypal-smart-payment-script')) { var script = document.createElement("script"); script.type = "module"; script.id = "paypal-smart-payment-script"; script.src = "https://cdn02.plentyone.com/7ukspn3affoc/plugin/23/paypal/js/smartPaymentScript.min.js"; script.setAttribute("data-client-id", "AfslQana4f4CQjHvRBnUc6vBJg5jgJuZFwM-SbrTiGKUAqB7MrxQv3QWFdQ6U1h7ogMDokT1DNBzRxMw"); script.setAttribute("data-user-id-token", ""); script.setAttribute("data-merchant-id", "HAR2LLRJHKH66"); script.setAttribute("data-currency", "EUR"); script.setAttribute("data-append-trailing-slash", ""); script.setAttribute("data-locale", "en_GB"); script.setAttribute("sandbox", ""); script.setAttribute("googlePayComponent", 0); script.setAttribute("applePayComponent", 0); script.setAttribute("logToken", "888ebd1e9470fe0c5126abfb3a028ddf"); document.body.appendChild(script); } else { var script = document.getElementById('paypal-smart-payment-script'); script.src = "https://cdn02.plentyone.com/7ukspn3affoc/plugin/23/paypal/js/smartPaymentScript.min.js"; script.setAttribute("data-client-id", "AfslQana4f4CQjHvRBnUc6vBJg5jgJuZFwM-SbrTiGKUAqB7MrxQv3QWFdQ6U1h7ogMDokT1DNBzRxMw"); script.setAttribute("data-user-id-token", ""); script.setAttribute("data-merchant-id", "HAR2LLRJHKH66"); script.setAttribute("data-currency", "EUR"); script.setAttribute("data-append-trailing-slash", ""); script.setAttribute("data-locale", "en_GB"); script.setAttribute("sandbox", ""); script.setAttribute("googlePayComponent", 0); script.setAttribute("applePayComponent", 0); script.setAttribute("logToken", "888ebd1e9470fe0c5126abfb3a028ddf"); }
if (typeof paypal_plenty_sdk === 'undefined' || typeof renderPayPalButtons !== 'function') { document.addEventListener('payPalScriptInitialized', () => { renderPayPalButtons('6b04e9ff8a5f3', 'paypal', 'buynow', 'rect', 'gold'); }); } else { renderPayPalButtons('6b04e9ff8a5f3', 'paypal', 'buynow', 'rect', 'gold'); }
if(!document.getElementById('paypal-smart-payment-script')) { var script = document.createElement("script"); script.type = "module"; script.id = "paypal-smart-payment-script"; script.src = "https://cdn02.plentyone.com/7ukspn3affoc/plugin/23/paypal/js/smartPaymentScript.min.js"; script.setAttribute("data-client-id", "AfslQana4f4CQjHvRBnUc6vBJg5jgJuZFwM-SbrTiGKUAqB7MrxQv3QWFdQ6U1h7ogMDokT1DNBzRxMw"); script.setAttribute("data-user-id-token", ""); script.setAttribute("data-merchant-id", "HAR2LLRJHKH66"); script.setAttribute("data-currency", "EUR"); script.setAttribute("data-append-trailing-slash", ""); script.setAttribute("data-locale", "en_GB"); script.setAttribute("sandbox", ""); script.setAttribute("googlePayComponent", 0); script.setAttribute("applePayComponent", 0); script.setAttribute("logToken", "888ebd1e9470fe0c5126abfb3a028ddf"); document.body.appendChild(script); } else { var script = document.getElementById('paypal-smart-payment-script'); script.src = "https://cdn02.plentyone.com/7ukspn3affoc/plugin/23/paypal/js/smartPaymentScript.min.js"; script.setAttribute("data-client-id", "AfslQana4f4CQjHvRBnUc6vBJg5jgJuZFwM-SbrTiGKUAqB7MrxQv3QWFdQ6U1h7ogMDokT1DNBzRxMw"); script.setAttribute("data-user-id-token", ""); script.setAttribute("data-merchant-id", "HAR2LLRJHKH66"); script.setAttribute("data-currency", "EUR"); script.setAttribute("data-append-trailing-slash", ""); script.setAttribute("data-locale", "en_GB"); script.setAttribute("sandbox", ""); script.setAttribute("googlePayComponent", 0); script.setAttribute("applePayComponent", 0); script.setAttribute("logToken", "888ebd1e9470fe0c5126abfb3a028ddf"); }

* Excl. VAT excl. Shipping

Vötsch


Type: VCL 7010
air-cooled
Test chamber volume approx. 100 liters
Test chamber dimensions: Width 490 mm Depth 400 mm Height 500 mm
External dimensions: Width 745 mm Depth 980 mm Height 1860 mm
Data for temperature tests:
Temperature range -70°C to +180°C
Temperature deviation over time ± 0.3 to ± 1 K
Temperature homogeneity spatially ± 0.5 to ± 2 K
                                                                           
Heating change rate 3.5 K/min
Cooling change rate 3.5 K/min
Data for climate tests:
Temperature range +10 to 95°C
Humidity range 10 to 98% r.H.
Temperature deviation over time ± 0.3 to ± 0.5 K
Temperature homogeneity spatially ± 0.5 to ± 1.5 K
Humidity deviation over time in the center of the usable space ± 1 to ± 3 %r.H.
Electrical connection 1/N/PE AC 230V ±10%, 50Hz, 15.2 A
Rated power, max. 3.5kW
Standard equipment:
1 pipe passage 50 mm ∅, 80 mm ∅
Refrigerants R23 & R404A
Weight approx. 210 kg
For your safety as a buyer, the following information!
The following points will be carried out on our offered chambers in advance:
1. Function check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are reserved!)
We are happy to answer any further questions by phone.

document.querySelector("form > input[data-mail='subject']").value = "Webshop - Frage zu Artikel - Artikel-ID: " + vueApp.$store.state.items[24072].variation.documents[0].data.item.id;

Switch to environmentally friendly refrigerant

The following work can be performed on climate chambers. Please contact us if you are interested.

 

  • Extraction and proper disposal of the previous refrigerant
  • Replacement of necessary components, if unavoidable
  • Evacuate the circuit and refill it with R 452A, for example.
  • Checking / adjusting overheating in expansion valves
  • Leak test
  • Test run of the system