Vötsch Climate Test Chamber VC 4018 190 Liters -45°C to +180°C


Item ID: 23407

Condition: Used

Stock: Only ${ $store.getters['23407/currentItemVariation'].stock.net } in stock

PAYMENT METHODS:

²


* Excl. VAT excl. Shipping

Vötsch


Here we offer this climate test chamber.
Air-cooled
Test chamber dimensions: Width 580 x Depth 450 x Height 750 mm
Housing dimensions: 870 x 1550 x 1800 mm
Temperature range: -45 °C to +180 °C
Temporal temperature fluctuation: ±0.1 to ±0.5 K
Spatial temperature fluctuation: ±0.5 to ±1.5 K
Rate of temperature change according to IEC 60068-3-5
Heating: 4 K/min.
Cooling: 3.5 K/min.
Humidity range: 10% to 98% r.H.
Temperature range at humidity: +10 °C to +95 °C
Temporal temperature fluctuation: ±0.1 to ±0.3 K
Spatial temperature fluctuation: ±0.5 to ±1 K
Temporal humidity fluctuation: ±0.1 to ±0.5 % r.H.
Test chamber volume: 190 liters
Refrigerant: R404a
3/N/PE AC 400V ±10% 50 Hz
Rated power: 4.1 kW
Rated current: 12.5 A
Weight: approx. 425 kg
Type: VC 4018
For your safety as a buyer, the following information!
The following points will be carried out on our offered chambers in advance:
1. Function check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are reserved!)
We are happy to answer any further questions by phone.

document.querySelector("form > input[data-mail='subject']").value = "Webshop - Frage zu Artikel - Artikel-ID: " + vueApp.$store.state.items[23407].variation.documents[0].data.item.id;

Switch to environmentally friendly refrigerant

The following work can be performed on climate chambers. Please contact us if you are interested.

 

  • Extraction and proper disposal of the previous refrigerant
  • Replacement of necessary components, if unavoidable
  • Evacuate the circuit and refill it with R 452A, for example.
  • Checking / adjusting overheating in expansion valves
  • Leak test
  • Test run of the system

Climate test cabinets

Show all