Vötsch Climate Test Chamber VC 4018 190 Liters -40°C to +180°C
Item ID: 23947
Condition: Used
Stock: Only ${ $store.getters['23947/currentItemVariation'].stock.net } in stock
PAYMENT METHODS:
²
* Excl. VAT excl. Shipping
Vötsch
Type: VC 4018
Air-cooled
Test chamber dimensions: Width 580 mm Depth 450 mm Height 750 mm
Housing dimensions: Width 870 mm Depth 1550 mm Height 1800 mm
Temperature range: -40°C to +180°C
Temporal temperature fluctuation: ±0.1 to ±0.5 K
Spatial temperature fluctuation: ±0.5 to ±1.5 K
Rate of temperature change according to IEC 60068-3-5
Heating: 4 K/min.
Cooling: 3.5 K/min.
Humidity range: 10% to 98% r. H.
Temperature range at humidity: +10°C to +95°C
Temporal temperature fluctuation: ±0.1 to ±0.3 K
Spatial temperature fluctuation: ±0.5 to ±1 K
Temporal humidity fluctuation: ±0.1 to ±0.5 % r.H.
Test chamber volume: 190 liters
Refrigerant: R404a
3/N/PE AC 400V 10% 50 Hz
Rated power: 4.9 kW Rated current: 9.0A
Weight: approx. 425 kg
For your safety as a buyer, the following information!
The following points will be carried out on our offered chambers in advance:
1. Function check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are reserved!)
We are happy to answer any further questions by phone.
Switch to environmentally friendly refrigerant
The following work can be performed on climate chambers. Please contact us if you are interested.
- Extraction and proper disposal of the previous refrigerant
- Replacement of necessary components, if unavoidable
- Evacuate the circuit and refill it with R 452A, for example.
- Checking / adjusting overheating in expansion valves
- Leak test
- Test run of the system