Vötsch Climate Test Chamber 990 Liters VCS 7100-5 -70°C to +180°C with Humidity


Item ID: 23479

Condition: Used

Stock: Only ${ $store.getters['23479/currentItemVariation'].stock.net } in stock

The item is already sold

* Excl. VAT excl. Shipping

Vötsch Climate Test Chamber


Here we offer a Vötsch climate chamber.
Vötsch Climate Test Chamber Water-Cooled
Technical Data:
Test Chamber Designation: VCS 7100-5
External Dimensions with Hinges and Door Lock
Height 1995 mm, Width 1680 mm, Depth 1855 mm
External Dimensions without Hinges and Door Lock
Height 1995 mm, Width 1300 mm, Depth 1855 mm
Internal Dimensions Height 950 mm, Width 1100 mm, Depth 950 mm
Test Chamber Volume: approx. 990 liters
Pass-Throughs:
The test chamber is equipped with pass-throughs on the right and left sides.
These allow measurement lines and testing devices to be placed in the test chamber.
2 X R1 NW 125 mm
2 X L1 NW 50 mm
Data for Temperature Tests:
Temperature Range -70°C to 180°C
Temperature Deviation over Time in Center of Usable Space ± 0.1 to ± 0.5 K
Spatial Temperature Deviation ± 0.5 to ± 2 K
Temperature Gradient 1 to 4 K
Rate of Temperature Change
Heating 6.1 K/min
Cooling 6 K/min
Heat Compensation at +20°C 5000 W
Heat Compensation at -20°C 5000 W
Data for Climate Tests:
Climate Test Chamber: VCS 7100-5
Temperature Range +10°C to +95°C
Humidity Range 10 to 98 %r.H.
Temperature Deviation over Time in Center of Usable Space ± 0.1 to ± 0.3 K
Spatial Temperature Deviation ± 0.5 to ± 1 K
Temperature Gradient 1 to 2 K
Humidity Fluctuation over Time in Center of Usable Space ± 1 to ± 3 %r.H.
Heat Compensation
in the range of +25°C to +95°C at a relative humidity
up to 90% 500W
3/N/PE AC 400V ±10% 50Hz
Rated Power: 18.0 kW
Rated Current: 29.0 A
Fuse on Site: 63 A slow
max. Heat Output to Environment: 2.2 kW
Permissible Test Load Weight
Total Load of Shelf Supports 100 kg, Test Chamber Floor 150 kg, Insert Shelf 50 kg
Weight: 910 kg
Type: VCS 7100-5
For your safety as a buyer, the following information!
 
The following points will be carried out in advance on our offered chambers:
1. Function check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. After successful inspection, the chambers will undergo a test run monitored with calibrated devices.
Condition: used
Scope of Delivery: (See Image)
(Changes and errors in the technical data, specifications are reserved!)
We are happy to answer any further questions by phone.
 

Technical characteristic Value
Item ID 23479
Condition Used
Model Vötsch VCS 7100-5
Manufacturer Vötsch
Weight 950000 g
document.querySelector("form > input[data-mail='subject']").value = "Webshop - Frage zu Artikel - Artikel-ID: " + vueApp.$store.state.items[23479].variation.documents[0].data.item.id;

EU Responsible Person

Weiss Technik GmbH
Greizer Straße 41-49
35447 Reiskirchen Germany
info@weiss-technik.com
+49 6408 84-0

Manufacturer details

Vötsch
Weiss Technik GmbH
Germany

Switch to environmentally friendly refrigerant

The following work can be performed on climate chambers. Please contact us if you are interested.

 

  • Extraction and proper disposal of the previous refrigerant
  • Replacement of necessary components, if unavoidable
  • Evacuate the circuit and refill it with R 452A, for example.
  • Checking / adjusting overheating in expansion valves
  • Leak test
  • Test run of the system