Vötsch Chamber for temperature and climate testing optimized for battery tests VCZ 60006/-1/S -60 to +160 7.5m³


Item ID: 25129

Condition: Used

Stock: Only ${ $store.getters['25129/currentItemVariation'].stock.net } in stock

PAYMENT METHODS:

²


* Excl. VAT excl. Shipping

Vötsch


Type: VCZ 60006/-1/S
The system was used for battery testing
Inert gas connection and pressure equalization flap

+Fresh air flushing approx. 100m³/h
Water-cooled
Large chamber system for temperature and climate testing
Test chamber volume: approx. 7.5m³
Internal dimensions: approx. Height 1480mm Width 2470mm Depth 2050mm
External dimensions: approx. Height 2400mm Width 3200mm Depth 4270mm
Test chamber floor load capacity: 3000kg/m²
Data for temperature testing:
Temperature range: -40°C to +160°C
Heating in the range -40 to +100°C: approx. 1 K/min
Cooling in the range +100 to -40°C: approx. 1.5 K/min
Heat compensation up to -40°C +20°C: 8000 W
Data for climate testing:
Temperature range: +10 to +80°C
Humidity range: 10 to 90 % r.H.
Dew point range: +5 to +77.4°C
Temperature deviation over time: +/-0.1 to +/- 0.5 K
Humidity deviation over time: +/- 3 to +/- 5% r.H.
Data for operation:
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal power: 25 kW
Nominal current: 41 A

Weight 3500 KG
Refrigerant R-404A / R-23 6.5 kg & 3.2 kg
For your safety as a buyer, the following information!
 
The following points will be carried out on our offered chambers in advance:
1. Function check and replacement of necessary components
2. Leak test with certificate
3. After successful inspection, the chambers will undergo a test run monitored with calibrated devices.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are reserved!)
We are happy to answer any further questions by phone.
For detailed technical data and processing instructions, we strongly recommend consulting the original data sheets or obtaining information directly from the manufacturer.

document.querySelector("form > input[data-mail='subject']").value = "Webshop - Frage zu Artikel - Artikel-ID: " + vueApp.$store.state.items[25129].variation.documents[0].data.item.id;

Switch to environmentally friendly refrigerant

The following work can be performed on climate chambers. Please contact us if you are interested.

 

  • Extraction and proper disposal of the previous refrigerant
  • Replacement of necessary components, if unavoidable
  • Evacuate the circuit and refill it with R 452A, for example.
  • Checking / adjusting overheating in expansion valves
  • Leak test
  • Test run of the system

Walk-in climate test cabinets