TIRA Walk-in Climate Simulation Chamber KB 127 TCZ 4022 S -2K Temperature Range: -40 to +140°C
Item ID: 23515
Condition: Used
Stock: Only ${ $store.getters['23515/currentItemVariation'].stock.net } in stock
EUR 44,000.00
*
Content
1 piece
Unit price
EUR 44,000.00 / piece
The item is in stock
PAYMENT METHODS:
²

* Excl. VAT excl. Shipping
TIRA
Type: TCZ 4022 S -2K
Description: Climate Simulation Chamber Air-Cooled
System Configuration:
The system consists of the following main components:
Walk-in, Insulated Chamber
Air Treatment Room
Humidification System
Machine Room
Control Cabinet
The insulated chamber forms the test area and includes the air treatment room.
In the air treatment room, the air is conditioned (cooling/heating) and
climatized (humidified and dehumidified) as well as circulated by a fan.
An external humidifier provides the necessary water vapor for
humidification.
The machine unit supplies the air treatment room with the
required energy through the refrigeration components (evaporator and dehumidifier).
The control cabinet houses all control and regulation units as well as
electrical components.
The control system ensures constant temperature regulation and a stable
regulation behavior.
The control panel allows for comprehensive operation.
Technical Data:
Performance Range for Temperature Testing:
Temperature Range -40...+140°C
Temperature Consistency, In the Supply Air: (temporal) ≤ ± 0.5°C
without thermal test chamber load according to (DIN 50011 Τ13) EN 60068
Temperature Consistency, In the Supply Air: (spatial) ≤ ± 1.0°C
without thermal test chamber load according to (DIN 50011) EN 60068
Heating Rate (according to DIN 50011) approx. 2.0 K/min
without thermal test chamber load (according to DIN 50011)
EN 60068) or test specimen in the temperature range of -30°C...+85°C
Cooling Rate (according to DIN 50011) approx. 2.0 K/min
without thermal test chamber load (according to DIN 50011)
EN 60068) or test specimen in the temperature range of -30°C...+85°C
Performance Range for Climate Testing:
Temperature Range +10...+90°C
Humidity Operating Range 10...approx. 95% r.H
without thermal test chamber measurement
Dew Point Temperature Range +5...+89°C
without thermal test chamber measurement
Humidity Consistency (in the supply air) (temporal) ≤ ± 2.5% r.H
measured in the supply air
Performance Range for Climate Testing with Heat Compensation
Temperature Range +15...+80°C
Humidity 15...approx. 80% r.H
without thermal test chamber load
with max. 16 kW heat compensation
Dew Point Temperature Range +10...+74°C
without thermal test chamber measurement
Dimensions: Test Chamber (WxDxH) approx. 2260 x 4648 x 2260 mm
Dimensions: External Dimensions (WxDxH) approx. 2660 x 6460 x 2800 mm
Clear Door Passage Test Chamber Door (WxH) 2260 x 2260 mm
Climate Module KB 127 (WxDxH) 1700 x 800 x 1400 mm
Control Cabinet (WxHxD) 800 x 500 x 2000 mm
Design:
Air Flow: Supply Air: Perforated Sheet at the Back Wall, in the Ceiling Area
Exhaust Air: Perforated Sheet at the Back Wall, in the Floor Area
Temperature Control:
Direct cooling through evaporation of
refrigerant in a finned heat exchanger:
Heating with electric resistance heater
Dehumidification:
Direct dehumidification through evaporation of
refrigerant in a heat exchanger
Interior Cladding: Stainless Steel
Exterior Cladding: Steel Sheet, galvanized, plastic-coated
Floor Design: Stainless Steel,
Floor Load 15000 N/m²
Wheel Load (Contact Area ≥ 4cm²) 1500 N/WheelDoor: Double-leaf Door, Stainless Steel, painted outside with
Viewing Window (WxH) 1000 x 1000 mm
Test Chamber Lighting: 4 Spotlights of 500 W each
Insulation Two-layer insulation, 80 mm PUR foam,
120 mm mineral wool
Refrigeration Unit (1 piece) Bltzer 6G-30.2Y
Refrigerant, R449A!
Refrigeration Machine Oil SEZ 32
Steam Humidifier (1 piece) EDB 40Color Scheme:
Chamber RAL9010, white
Door RAL9010, white
Machine Unit RAL 7032, pebble grey
Control Cabinet RAL 7032, pebble grey
Weights:
Total System
(includes machine set, control cabinet, and humidification system) approx. 4900 kg
Machine Set KB 127 approx. 750 kg
Control Cabinet approx. 120 kg
Humidification System approx. 64 kgConnections:
Nominal Voltage 400 V +6%/-10% 3/PE 50Hz
Nominal Power 95 kW
Nominal Current 150 A
Fixed Connection
Site-specific Protection 200 A slow
Main Switch installed in the control cabinet housing
Humidification Water according to installation plan
Water Supply and Drainage according to installation plan
Weight: approx. 5834 kg
Condition: used
Scope of Delivery: (See Image)
(Changes and errors in technical data are reserved!)
Further questions can be answered by phone.
| Technical characteristic | Value |
|---|---|
| Item ID | 23515 |
| Condition | Used |
| Model | TIRA Begehbare Klimazelle |
| Manufacturer | TIRA |
| Weight | 5834000 g |
EU Responsible Person
TIRA GmbH
Eisfelder Strasse 23/25
96528 Schalkau
Germany
info@tira-gmbh.de
+49 367 66280-0
Manufacturer details
TIRA
TIRA GmbH
Germany
Switch to environmentally friendly refrigerant
The following work can be performed on climate chambers. Please contact us if you are interested.
- Extraction and proper disposal of the previous refrigerant
- Replacement of necessary components, if unavoidable
- Evacuate the circuit and refill it with R 452A, for example.
- Checking / adjusting overheating in expansion valves
- Leak test
- Test run of the system
Climate test cabinets
Binder Safety Vacuum Drying Oven for Flammable Solvents VDL 115
EUR 7,500.00 *
The item is in stock
* Excl. VAT
excl.
Shipping
Test cabinet for lithium-ion energy storage BINDER KB 720 with equipment package P Plus
EUR 14,200.00 *
The item is in stock
* Excl. VAT
excl.
Shipping
Zwick / Roell Temperature Chamber for AllroundLine Temp. -80°C to + 250°C EC76G 1-1-2-0 361763
EUR 8,000.00 *
The item is in stock
* Excl. VAT
excl.
Shipping
BINDER KB 720 Cooling Incubator with Package P Plus – Battery Testing Chamber EUCAR 5, CO₂ Fire Extinguishing System
EUR 14,200.00 *
The item is in stock
* Excl. VAT
excl.
Shipping
Angelantoni Walk-In Climate Chamber ACS WZH10-4080-2 BT – Optimized for Battery Testing (Li-Ion)
EUR 48,000.00 *
The item is in stock
* Excl. VAT
excl.
Shipping
Weiss Climate Test Chamber WK 10/40-80 Walk-In / Optimized for Battery Testing
EUR 46,000.00 *
The item is in stock
* Excl. VAT
excl.
Shipping
Weiss Climate Test Chamber WK11-600/70/5 with Humidity, approx. 600 Liters, −70 °C to +180 °C
EUR 24,500.00 *
The item is in stock
* Excl. VAT
excl.
Shipping
Weiss Technik TempEvent T/340/40/3/S Temperature Test Chamber –40 °C to +180 °C, Year 2021
EUR 29,500.00 *
The item is in stock
* Excl. VAT
excl.
Shipping
Weiss Technik TempEvent T/340/40/3/S Temperature Test Chamber –40 °C to +180 °C, Year 2021
EUR 29,500.00 *
The item is in stock
* Excl. VAT
excl.
Shipping
CTS Temperature & Climate - Air Conditioning Unit CSR-60/810/S –60 °C to +170 °C with Test Box 1200 L
EUR 85,000.00 *
The item is in stock
* Excl. VAT
excl.
Shipping
Industrial Drying Oven Amboss + Langbein WTS 20 3B 80 °C - 400 V 5 kW
EUR 1,450.00 *
The item is in stock
* Excl. VAT
excl.
Shipping
Binder switching climate chamber MKF 115 E3.1 -40°C to 180°C with humidity
EUR 7,000.00 *
The item is in stock
* Excl. VAT
excl.
Shipping
Binder Material Testing Chamber FP 115 with forced circulation 300°C 115 liters 230 V
EUR 750.00 *
The item is in stock
* Excl. VAT
excl.
Shipping
Carbolite GERO Muffle Furnace ELF 11/6B – 1100 °C Year of Manufacture 2021
EUR 850.00 *
The item is in stock
* Excl. VAT
excl.
Shipping
Vötsch VC³ 4018/S Climate Test Chamber Li-Ion CO/CO₂ -42 to +150 °C 400 V 190 Liters
EUR 29,500.00 *
The item is in stock
* Excl. VAT
excl.
Shipping
Espec Climate Test Chamber PL-2KPH -40°C to 180°C with Humidity
EUR 9,000.00 *
The item is in stock
* Excl. VAT
excl.
Shipping