Electrical Power Supply:
Total power 17 KVA
Current draw 32 A
Main fuse 3 x 35 A slow
Main supply line 5 x 6 mm2
Connection specifications 3 x 400V / N / PE / 50Hz
Temperature:
Temperature range from; - 45°C to +180°C
Time deviation; +/- 0.5 °K according to DIN 50011 with
empty test chamber
Average heating time Average cooling time (according to DIN 50011 Part 2)
approx. 2 °K/min approx. 2 "K/min
Water Connections:
Cooling water inlet
Cooling water outlet
Water inlet
Water outlet
R 3/4", 3 bar, max. 15°C
R 3/4", 2.7 bar
R1, bar omitted
R 1/2 " 0 bar
Sound Level:
Chamber approx. 68 dB(A)
measured at 1m distance in free field
Dimensions:
Chamber W 1390 mm / H 2390 mm / D 2550 mm
Weight:
Chamber approx. 1250 kg
Other
Refrigerant R 404A
Working Climate Range:
Temperature Humidity
12°C to 30°C
25% to 75% rel.H.
Type: KKC 2/45
Scope of delivery. (See pictures)
(Changes and errors in the technical data, specifications are reserved!)
 
We would be happy to answer any further questions by phone.
Written orders possible via email or fax

Technical characteristic Value
Item ID 16025
Condition Used
Model RS-Simulatoren Klimaprüfkammer KKC 2/45
Manufacturer RS Simulatoren
Weight 1250000 g
document.querySelector("form > input[data-mail='subject']").value = "Webshop - Frage zu Artikel - Artikel-ID: " + vueApp.$store.state.items[16025].variation.documents[0].data.item.id;

EU Responsible Person

RS-Simulatoren Prüf- und Meßtechnik GmbH
Niebuhrstr. 59
46049 Oberhausen Germany
info@rs-simulatoren.de
+49 208 / 299 52-0

Manufacturer details

RS Simulatoren
RS-Simulatoren Prüf- und Meßtechnik GmbH
Germany

Switch to environmentally friendly refrigerant

The following work can be performed on climate chambers. Please contact us if you are interested.

 

  • Extraction and proper disposal of the previous refrigerant
  • Replacement of necessary components, if unavoidable
  • Evacuate the circuit and refill it with R 452A, for example.
  • Checking / adjusting overheating in expansion valves
  • Leak test
  • Test run of the system

Climate test cabinets