HSR Process Technology Climate Test Chamber


We offer an HSR Process Technology Climate Test Chamber.

Water-cooled
The connection to the power grid is designed as a CEKON plug connection.
Technical Data:
External dimensions: Width 1800 mm x Depth 2300 mm x Height 2170 mm
Internal dimensions: Width 1500 mm x Depth 1030 mm x Height 1000 mm
Door dimensions: Width 1500 mm x Height 1000 mm

Electrical connection: 400 V/3/50/39.00 kW
Connection cable: 5 meters with CEKON plug device 63 A
Sound pressure level approx. 80 dBa at 1 meter
Permissible temperature range of usable space: - 40°C ... +100°C
Temperature hysteresis: +/- 1K
Cooling capacity: approx. 6 K/min in the temperature range of +100°C ... -40°C according to DIN 50011
Heating capacity: in the temperature range of - 40°C ... +100°C according to DIN 50011
neutral water without particles
Maximum operating pressure: 10 bar
Minimum differential pressure: 2.5 bar
Cooling water connection: Pipe thread G 1 1/4"
Weight of the chamber: approx. 800 kg
Refrigerant: R 404A
Type: P01031001
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are reserved!)
We are happy to answer any further questions by phone.

Technical characteristic Value
Item ID 21307
Condition Used
Model HSR Klimaprüfschrank
Manufacturer HSR Verfahrenstechnik
Weight 800000 g
document.querySelector("form > input[data-mail='subject']").value = "Webshop - Frage zu Artikel - Artikel-ID: " + vueApp.$store.state.items[21307].variation.documents[0].data.item.id;

EU Responsible Person

Manufacturer details

HSR Verfahrenstechnik

Switch to environmentally friendly refrigerant

The following work can be performed on climate chambers. Please contact us if you are interested.

 

  • Extraction and proper disposal of the previous refrigerant
  • Replacement of necessary components, if unavoidable
  • Evacuate the circuit and refill it with R 452A, for example.
  • Checking / adjusting overheating in expansion valves
  • Leak test
  • Test run of the system