HS Simulators Climate Test Chamber HS 2050 K 45 -45 / + 180°C


Item ID: 19949

Condition: Used

Stock: Only ${ $store.getters['19949/currentItemVariation'].stock.net } in stock

The item is already sold

* Excl. VAT excl. Shipping

HS Simulators Climate Test Chamber


Here we offer an HS Simulators Climate Test Chamber.
HS Simulators Climate Test Chamber
Door Window 560x560
Pass-through 2x100 1x left 1x right
Internal dimensions: Width 1010 mm, Depth 2010 mm, Height 1010 mm
External dimensions: Width 1300 mm, Depth 2700 mm, Height 2100 mm
Total power: 20 KVA
Current consumption: 32 A
Main fuse: 3 x 50 A, slow
Main supply line: 5 x 10 mm2
Connection voltage: 380 V; 3/Nni 50 Hz
Temperature
Temperature range from -45°C / +180°C
Time control accuracy ±0.5°C
Spatial control accuracy ±0.8°C
Cooling time from +180°C to -40°C in approx. 60 min.
Heating time from +20°C to +180°C in approx. 30 min.
Humidity:
 
According to the diagram, humidity from 10% to 98%
Time control accuracy 1-3%
Spatial control accuracy +5%
at atmospheric pressure.
Refrigerant R 404A
Type: HS 2050 K 45
For you as a buyer, the following information for your safety!
 
The following points will be carried out on our offered chambers in advance:
1. Function check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will undergo a test run monitored with calibrated devices.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are reserved!)
 
We are happy to answer any further questions by phone.

Technical characteristic Value
Item ID 19949
Condition Used
Model HS-Simulatoren HS 2050 K 45
Manufacturer HS Simulatoren
Weight 600000 g
document.querySelector("form > input[data-mail='subject']").value = "Webshop - Frage zu Artikel - Artikel-ID: " + vueApp.$store.state.items[19949].variation.documents[0].data.item.id;

EU Responsible Person

Manufacturer details

HS Simulatoren

Switch to environmentally friendly refrigerant

The following work can be performed on climate chambers. Please contact us if you are interested.

 

  • Extraction and proper disposal of the previous refrigerant
  • Replacement of necessary components, if unavoidable
  • Evacuate the circuit and refill it with R 452A, for example.
  • Checking / adjusting overheating in expansion valves
  • Leak test
  • Test run of the system

Climate test cabinets