Heraeus Vötsch Temperature Test Chamber VT 7100 -70°C to +180°C 1035 l (521/83231)


Item ID: 21972

Condition: Used

Stock: Only ${ $store.getters['21972/currentItemVariation'].stock.net } in stock

The item is already sold

* Excl. VAT excl. Shipping

Vötsch


Type: VT 7100 / 521/83231
Vötsch Temperature Test Chamber Water-Cooled
Test Chamber Volume 1035 Liters
Test Chamber Dimensions: Width 1000 mm Depth 1150 mm Height 900 mm
Temperature Range -70°C to +180°C
Temporal Temperature Deviation ±0.5 K
Spatial Temperature Deviation ±1.5 K
Cooling Temperature Change Rate 1.5 K/min
Heating Temperature Change Rate 2 K/min
Voltage 400 V +6/10% 3/N 50Hz
Rated Power 8.6 kW
Rated Current 17 A
Refrigerant: R-404 A / R 23
Weight: approx. 805 kg
For your safety as a buyer, the following information!
The following points will be carried out on our offered chambers in advance:
1. Function check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will undergo a documented test run.
Condition: used
Scope of Delivery: (See Image)
(Changes and errors in technical data are reserved!)
We would be happy to answer any further questions by phone.

Technical characteristic Value
Item ID 21972
Condition Used
Model Klimaprüfschrank VT 7011
Manufacturer Heraeus Vötsch
Weight 805000 g
document.querySelector("form > input[data-mail='subject']").value = "Webshop - Frage zu Artikel - Artikel-ID: " + vueApp.$store.state.items[21972].variation.documents[0].data.item.id;

EU Responsible Person

Weiss Technik GmbH
Greizer Straße 41-49
35447 Reiskirchen Germany
info@weiss-technik.com
+49 6408 84-0

Manufacturer details

Heraeus Vötsch
Weiss Technik GmbH
Greizer Straße 41-49
35447 Reiskirchen Germany
info@weiss-technik.com
+49 6408 84-0

Switch to environmentally friendly refrigerant

The following work can be performed on climate chambers. Please contact us if you are interested.

 

  • Extraction and proper disposal of the previous refrigerant
  • Replacement of necessary components, if unavoidable
  • Evacuate the circuit and refill it with R 452A, for example.
  • Checking / adjusting overheating in expansion valves
  • Leak test
  • Test run of the system

Climate test cabinets