Heraeus Vötsch Pharmaceutical Plant Growth Cabinet VB 1000 Pharma 1000 Liters


Item ID: 13055

Condition: Used

Stock: Only ${ $store.getters['13055/currentItemVariation'].stock.net } in stock

The item is already sold

* Excl. VAT excl. Shipping

Heraeus Vötsch Pharmaceutical Plant Growth Cabinet


Here we offer you a Heraeus Vötsch Pharmaceutical Plant Growth Cabinet.
Temperature range +5°C to +45°C
Humidity range from 25% to 95% r.H.
Dew point range +4°C to +35°C
Test chamber stainless steel 1000 liters
Internal dimensions (WxDxH) 820 x 780 x 1400 mm
Maximum load of the test chamber floor 150 kg
per shelf 20 kg
Total load 150 kg
1-door with observation window
 29 shelves
Refrigerant R404A
Interface RS 232 for external computer control
Nominal voltage 1/N/PE AC 230 V ± 10% 50 Hz
Nominal power 2.4 kW
Nominal current 11.8 A
Pass-through NW 50 mm
Weight approx. 400 kg
Type: VB 1000 Pharma
For you as a buyer, the following information for your safety!
 
The following points will be carried out in advance on our offered chambers:
1. Function check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will undergo a test run monitored with calibrated devices.
Scope of delivery: VB 1000 Pharma
Condition: used
(Changes and errors in the technical data, specifications are reserved!)
 
We would be happy to answer any further questions by phone.

Technical characteristic Value
Item ID 13055
Condition Used
Model Heraeus Vötsch Pharmazeutischer Pflanzenwuchsschrank VB 1000 Pharma
Manufacturer Heraeus Vötsch
Weight 420000 g
document.querySelector("form > input[data-mail='subject']").value = "Webshop - Frage zu Artikel - Artikel-ID: " + vueApp.$store.state.items[13055].variation.documents[0].data.item.id;

EU Responsible Person

Weiss Technik GmbH
Greizer Straße 41-49
35447 Reiskirchen Germany
info@weiss-technik.com
+49 6408 84-0

Manufacturer details

Heraeus Vötsch
Weiss Technik GmbH
Greizer Straße 41-49
35447 Reiskirchen Germany
info@weiss-technik.com
+49 6408 84-0

Switch to environmentally friendly refrigerant

The following work can be performed on climate chambers. Please contact us if you are interested.

 

  • Extraction and proper disposal of the previous refrigerant
  • Replacement of necessary components, if unavoidable
  • Evacuate the circuit and refill it with R 452A, for example.
  • Checking / adjusting overheating in expansion valves
  • Leak test
  • Test run of the system

Climate test cabinets