Heraeus Vötsch Climate Chamber


Here we offer you a Heraeus Vötsch climate chamber.
Vötsch Climate Chamber VCS 7033
Temperature range: -70°C to +180°C
Temperature change rate:
Heating 7.5 K/min.
Cooling 6.5 K/min
Humidity range: 10% to 98% r.H.
Temporal temperature deviation ± 0.5 K
Spatial temperature deviation ± 1.5 K
Test chamber dimensions: Width 675 x Depth 650 x Height 520 mm

Housing dimensions: Width 930 x Depth 1565 x Height 1840 mm
Side passage 125mm
Approx. 330 L Weight: 600 kg

Voltage: 400V +/-10% 3/N 50Hz
Rated power 9.5 kW
Rated current 17 A
Refrigerant R404A / R23
Type: VCS 7033
For you as a buyer, the following information for your safety!
 
The following points will be carried out on our offered chambers in advance:
1. Function check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will undergo a test run monitored with calibrated devices.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are reserved!)
 
We are happy to answer any further questions by phone.
Written orders possible via email or fax

Technical characteristic Value
Item ID 18925
Condition Used
Model Heraeus Vötsch Klimaprüfschrank VCS 7033
Manufacturer Heraeus Vötsch
Weight 650000 g
document.querySelector("form > input[data-mail='subject']").value = "Webshop - Frage zu Artikel - Artikel-ID: " + vueApp.$store.state.items[18925].variation.documents[0].data.item.id;

EU Responsible Person

Weiss Technik GmbH
Greizer Straße 41-49
35447 Reiskirchen Germany
info@weiss-technik.com
+49 6408 84-0

Manufacturer details

Heraeus Vötsch
Weiss Technik GmbH
Greizer Straße 41-49
35447 Reiskirchen Germany
info@weiss-technik.com
+49 6408 84-0

Switch to environmentally friendly refrigerant

The following work can be performed on climate chambers. Please contact us if you are interested.

 

  • Extraction and proper disposal of the previous refrigerant
  • Replacement of necessary components, if unavoidable
  • Evacuate the circuit and refill it with R 452A, for example.
  • Checking / adjusting overheating in expansion valves
  • Leak test
  • Test run of the system