Heraeus Vötsch Climate Test Chamber VB 1514 +5°C to +45°C


Item ID: 9067

Condition: Used

Stock: Only ${ $store.getters['9067/currentItemVariation'].stock.net } in stock

The item is already sold

* Excl. VAT excl. Shipping

Heraeus Vötsch Climate Test Chamber


Here we offer you a Heraeus Vötsch Climate Test Chamber.

Air Cooling
Stability Test Chamber, temperature range +5°C to +45°C
Climate tests from 40% to 95% r.H. at +4°C to +35°C
Dehumidification and humidification system, test chamber made of stainless steel 1.4301
Internal dimensions (HxWxD) 1,600 x 800 x 2,000 mm,
2 doors with one observation window each,
26 shelves 800 x 800 mm,
Refrigerant R404A,
RS 232 interface for external computer control,
Connection 400V/50Hz/2.4kW,
CE marked, mobile, very good condition.
Weight approx. 740 kg
Type: VB 1514
For your safety as a buyer, the following information!
 
The following points will be carried out on our offered chambers in advance:
1. Function check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will undergo a test run monitored with calibrated devices.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are reserved!)
 
We would be happy to answer any further questions by phone.

Technical characteristic Value
Item ID 9067
Condition Used
Model Heraeus Vötsch Klimaprüfschrank VB 1514 +5°C bis + 45°C
Manufacturer Heraeus Vötsch
Weight 740000 g
document.querySelector("form > input[data-mail='subject']").value = "Webshop - Frage zu Artikel - Artikel-ID: " + vueApp.$store.state.items[9067].variation.documents[0].data.item.id;

EU Responsible Person

Weiss Technik GmbH
Greizer Straße 41-49
35447 Reiskirchen Germany
info@weiss-technik.com
+49 6408 84-0

Manufacturer details

Heraeus Vötsch
Weiss Technik GmbH
Greizer Straße 41-49
35447 Reiskirchen Germany
info@weiss-technik.com
+49 6408 84-0

Switch to environmentally friendly refrigerant

The following work can be performed on climate chambers. Please contact us if you are interested.

 

  • Extraction and proper disposal of the previous refrigerant
  • Replacement of necessary components, if unavoidable
  • Evacuate the circuit and refill it with R 452A, for example.
  • Checking / adjusting overheating in expansion valves
  • Leak test
  • Test run of the system