Eliog-kelvitherm Industrial Oven Curing Oven
Here we offer you an Eliog-kelvitherm Industrial Oven Curing Oven.
Industrial Oven Curing Oven
Application area:
The curing oven is suitable for heat treatment processes where no flammable solvents are released.
The curing oven is used for pre-drying CFC pipes.
Temperature range up to max. 100°C
Airflow vertical, from bottom to top
Recirculation fan 1 piece at 5.5 kW
Exhaust fan 1 piece at 120 W, frequency-controlled
Heating power 20 kW
Connection value 28 kVA
Nominal voltage 3 x 400 V; 50 Hz; PE
Protection class IP 54, IP 20 (heating)
Noise emission < 70 dB(A)
Average air speed in the usable space 0.5 ... 0.75 m/s
Outer wall temperature t<60°C (excluding thermal bridges),
at usable space temperature 100°C and ambient temperature 20°C
Loading door 1 swing frame door single-leaf, right-hinged
Maintenance door 1 revolving door, single-leaf split in height
Weight 3100 kg
Usable space equipment 1 rotating frame with 6 manually
extendable workpiece carriers
Usable space dimensions Height approx. 6500 mm Width approx. 1250 mm Depth approx. 1250 mm
Function description:
Heat transfer through flowing hot air (convection).
Airflow vertical, from bottom to top.
Air circulation via radial fan.
Heating via tubular heating elements.
Temperature control in the usable space, via electronic temperature controller and thyristor switch.
Device equipment:
Resistance thermometer
WO 61; 2x Pt 100; three-wire circuit TMG
d = 6 mm; 500 mm long; accuracy class A
Temperature controller KS 40-1 PMA
Temperature limiter (usable space) TB 40-1 PMA
Safety temperature limiter (heating) ATHf 70 and JUMO
Control Siemens PLC S7-300/313
Frequency converter SEW MCO7B 0003-5A3-4-00
Type: KU 100/65-12-12
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data, specifications are subject to change!)
We would be happy to answer any further questions by phone.
Switch to environmentally friendly refrigerant
The following work can be performed on climate chambers. Please contact us if you are interested.
- Extraction and proper disposal of the previous refrigerant
- Replacement of necessary components, if unavoidable
- Evacuate the circuit and refill it with R 452A, for example.
- Checking / adjusting overheating in expansion valves
- Leak test
- Test run of the system