Delta Environmental Test Chamber


Environmental Test Chamber Delta 1550 -70 H / A3398
– High-Performance Temperature Testing System (−70 °C to +150 °C)
Air-Cooled
Ideal for: Temperature cycles, climate tests, material qualification,
electronics, automotive, and aerospace applications
Technical Specifications:
Model: Delta 1550 -70 H / A3398
Temperature Range: −70 °C … +150 °C
Chamber Volume: 1,550 liters
Operating Modes: Constant temperature
Control: Precise PID controller / PLC with touchscreen
(7–10"), data logger, Ethernet/Modbus
Performance Characteristics
Cooling Rate: up to 10–15 K/min
Heating Rate: up to 10–15 K/min
Temperature Stability: ±0.3…0.5 °C
Temperature Uniformity: ±2…3 °C over usable volume
Heating Power: 20–60 kW (depending on configuration)
Cooling Power: two-stage cascade cooling system (CO₂ / HFO / HFC) for −70 °C
Mechanical Structure:
Interior: Stainless steel 1.4301 (V2A), hygienic with rounded corners
Outer Shell: Powder-coated steel frame, corrosion-resistant
Insulation: High-performance PUR / vacuum insulation panels (200–300 mm)
Door: insulated, with double glazing
Shelves: Stainless steel, adjustable, up to 200 kg per level
Pass-Throughs: Ø 25–125 mm
Defrosting: electrically controlled
Dimensions & Weight
External Dimensions (approx.): 1,400 × 2,000 × 2,200 mm (W × D × H)
Internal Dimensions (approx.): 1,000 × 1,550 × 1,000 mm (usable space)
Machine Module: 800 × 1,500 × 1,500 mm (side or rear mounted)
Power Supply: 3/N/PE AC 400V ±10% 50Hz
Rated Power 14.0 kW Rated Current 27 A
Refrigerant: R404A / R-23
Weight: 2100 kg
For your safety as a buyer, the following information!
The following points will be carried out on our offered chambers in advance:
1. Function check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will undergo a documented test run.
Condition: used
Scope of Delivery: (See image)
(Changes and errors in technical data are reserved!)
Further questions can be answered by phone.

Technical characteristic Value
Item ID 24879
Condition Used
Model Design Environmental
Manufacturer Weiss
Weight 2200000 g
document.querySelector("form > input[data-mail='subject']").value = "Webshop - Frage zu Artikel - Artikel-ID: " + vueApp.$store.state.items[24879].variation.documents[0].data.item.id;

EU Responsible Person

Weiss Technik GmbH
Greizer Straße 41-49
35447 Reiskirchen Germany
info@weiss-technik.com
+49 6408 84-0

Manufacturer details

Weiss
Weiss Technik GmbH
Germany

Switch to environmentally friendly refrigerant

The following work can be performed on climate chambers. Please contact us if you are interested.

 

  • Extraction and proper disposal of the previous refrigerant
  • Replacement of necessary components, if unavoidable
  • Evacuate the circuit and refill it with R 452A, for example.
  • Checking / adjusting overheating in expansion valves
  • Leak test
  • Test run of the system