CTS Temperature Shock Test Chamber TSS-70/350-A Warm: +50°C to +200°C Cold: -70°C to +100°C 350 liters


Item ID: 25163

Condition: Used

Stock: Only ${ $store.getters['25163/currentItemVariation'].stock.net } in stock

PAYMENT METHODS:

²

if(!document.getElementById('paypal-smart-payment-script')) { var script = document.createElement("script"); script.type = "module"; script.id = "paypal-smart-payment-script"; script.src = "https://cdn02.plentyone.com/7ukspn3affoc/plugin/23/paypal/js/smartPaymentScript.min.js"; script.setAttribute("data-client-id", "AfslQana4f4CQjHvRBnUc6vBJg5jgJuZFwM-SbrTiGKUAqB7MrxQv3QWFdQ6U1h7ogMDokT1DNBzRxMw"); script.setAttribute("data-user-id-token", ""); script.setAttribute("data-merchant-id", "HAR2LLRJHKH66"); script.setAttribute("data-currency", "EUR"); script.setAttribute("data-append-trailing-slash", ""); script.setAttribute("data-locale", "en_GB"); script.setAttribute("sandbox", ""); script.setAttribute("googlePayComponent", 0); script.setAttribute("applePayComponent", 0); script.setAttribute("logToken", "86cfa7f3fd4bba2d7590cf39e3027191"); document.body.appendChild(script); } else { var script = document.getElementById('paypal-smart-payment-script'); script.src = "https://cdn02.plentyone.com/7ukspn3affoc/plugin/23/paypal/js/smartPaymentScript.min.js"; script.setAttribute("data-client-id", "AfslQana4f4CQjHvRBnUc6vBJg5jgJuZFwM-SbrTiGKUAqB7MrxQv3QWFdQ6U1h7ogMDokT1DNBzRxMw"); script.setAttribute("data-user-id-token", ""); script.setAttribute("data-merchant-id", "HAR2LLRJHKH66"); script.setAttribute("data-currency", "EUR"); script.setAttribute("data-append-trailing-slash", ""); script.setAttribute("data-locale", "en_GB"); script.setAttribute("sandbox", ""); script.setAttribute("googlePayComponent", 0); script.setAttribute("applePayComponent", 0); script.setAttribute("logToken", "86cfa7f3fd4bba2d7590cf39e3027191"); }
if (typeof paypal_plenty_sdk === 'undefined' || typeof renderPayPalButtons !== 'function') { document.addEventListener('payPalScriptInitialized', () => { renderPayPalButtons('6b04ea8126676', 'paypal', 'buynow', 'rect', 'gold'); }); } else { renderPayPalButtons('6b04ea8126676', 'paypal', 'buynow', 'rect', 'gold'); }
if(!document.getElementById('paypal-smart-payment-script')) { var script = document.createElement("script"); script.type = "module"; script.id = "paypal-smart-payment-script"; script.src = "https://cdn02.plentyone.com/7ukspn3affoc/plugin/23/paypal/js/smartPaymentScript.min.js"; script.setAttribute("data-client-id", "AfslQana4f4CQjHvRBnUc6vBJg5jgJuZFwM-SbrTiGKUAqB7MrxQv3QWFdQ6U1h7ogMDokT1DNBzRxMw"); script.setAttribute("data-user-id-token", ""); script.setAttribute("data-merchant-id", "HAR2LLRJHKH66"); script.setAttribute("data-currency", "EUR"); script.setAttribute("data-append-trailing-slash", ""); script.setAttribute("data-locale", "en_GB"); script.setAttribute("sandbox", ""); script.setAttribute("googlePayComponent", 0); script.setAttribute("applePayComponent", 0); script.setAttribute("logToken", "86cfa7f3fd4bba2d7590cf39e3027191"); document.body.appendChild(script); } else { var script = document.getElementById('paypal-smart-payment-script'); script.src = "https://cdn02.plentyone.com/7ukspn3affoc/plugin/23/paypal/js/smartPaymentScript.min.js"; script.setAttribute("data-client-id", "AfslQana4f4CQjHvRBnUc6vBJg5jgJuZFwM-SbrTiGKUAqB7MrxQv3QWFdQ6U1h7ogMDokT1DNBzRxMw"); script.setAttribute("data-user-id-token", ""); script.setAttribute("data-merchant-id", "HAR2LLRJHKH66"); script.setAttribute("data-currency", "EUR"); script.setAttribute("data-append-trailing-slash", ""); script.setAttribute("data-locale", "en_GB"); script.setAttribute("sandbox", ""); script.setAttribute("googlePayComponent", 0); script.setAttribute("applePayComponent", 0); script.setAttribute("logToken", "86cfa7f3fd4bba2d7590cf39e3027191"); }

* Excl. VAT excl. Shipping

CTS


Type: TSS-70/350-A

Water-cooled cooling unit
For sale is a high-quality temperature shock test chamber from CTS
(Clima Temperatur Systeme), model TSS-70/350-A.
The device is used for conducting temperature shock tests
and is typically employed in industry, research, and quality assurance.
Applications:
Material testing
Aging tests
Electronics and component testing
Temperature shock and temperature cycling tests
Technical data:

Type: TSS-70/350-A
Temperature range:
Warm chamber: +50°C to +200°C
Cold chamber: -70°C to +100°C
Electrical data:
Connection: 400 V, 3/N, 50 Hz
Rated power: approx. 20.4 kW
Rated current: approx. 36.5 A
Cooling system:
Refrigerant: R404A / R23
Pre-cooling stage: approx. 6.0 kg
Cooling stage: approx. 3.0 kg
water-cooled
Features:
CTS control panel with touch display
Microprocessor-controlled regulation and monitoring system
Program operation
Digital setpoint and actual value display
2-zone system (warm and cold chamber)
Automatic lift for shock tests
Technical design:
Warm and cold chambers separated
Lift system for rapid temperature change
Test chamber made of stainless steel
Insert shelf / grid
Viewing window in the door
Water cooling connections available
Control cabinet integrated
Dimensions:
External dimensions (HxWxD): approx. 2450 x 2160 x 2200 mm
Internal dimensions (HxWxD): approx. 610 x 850 x 680 mm
Weight: approx. 2500 kg
Additional data:
Protection class: IP 54
Operating overpressure: approx. 25 bar
Test pressure: approx. 27.5 bar
For your safety as a buyer, the following information!
The following points will be carried out on our offered chambers in advance:
1. Function check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will undergo a documented test run.
Condition: used
Scope of delivery: see pictures
(Changes and errors in the technical data reserved!)
Further questions can be answered by phone.

document.querySelector("form > input[data-mail='subject']").value = "Webshop - Frage zu Artikel - Artikel-ID: " + vueApp.$store.state.items[25163].variation.documents[0].data.item.id;

Switch to environmentally friendly refrigerant

The following work can be performed on climate chambers. Please contact us if you are interested.

 

  • Extraction and proper disposal of the previous refrigerant
  • Replacement of necessary components, if unavoidable
  • Evacuate the circuit and refill it with R 452A, for example.
  • Checking / adjusting overheating in expansion valves
  • Leak test
  • Test run of the system

Climate test cabinets