CTS Temperature and Climate Air Conditioning Unit CR-60/200 200 Liters -60 to +170°C


Item ID: 24078

Condition: Used

Stock: Only ${ $store.getters['24078/currentItemVariation'].stock.net } in stock

The item is already sold

* Excl. VAT excl. Shipping

CTS


Type: CR-60/200
Temperature and Climate Air Conditioning Unit (Air-Cooled)
The type designation of the CTS cabinet series is composed as follows:
Type CR -60/200
1) C means: Climate
2) R means: external conditioning
3) -60 means: lower temperature -60 °C
4) 200 means: 200 liters test chamber volume
The device is used for temperature or climate control of external test chambers.
The connection is made via special temperature hoses for all devices.
Technical Performance Data:
Temperature Tests:
Temperature range -60°C to +170°C
Temperature deviation ±0.1 to ±0.5 K over time
Average temperature change rate,
measured with a short-circuited circuit
Heating 3 K/min
Cooling 3 K/min
in the range of +150°C to -40°C
Heat compensation max. 1500 W at +20°C
Climate Tests:
Temperature range +10 °C to +90 °C
Humidity range 10% to 95% relative humidity
Dew point range +5°C to +88°C
Temperature deviation ±0.1 to ±0.5 K over time
Humidity deviation ±0.5 to ±1.5 % r.H. over time
The technical data refer to an ambient temperature of +25 °C,
nominal voltage 400V, without test specimen, without heat compensation, and without additional devices.
Options may affect the performance data.
Dimensions:
Test volume 200 liters
Test chamber dimensions: Height 750, Width 650, Depth 400 mm
External dimensions: Height 1800, Width 920, Depth 1345 mm
Note:
Due to flow and heat losses within the hoses
and the on-site box, the maximum relative humidity is limited.
In the temperature range of +20°C to +60°C, approximately 90-95% r.H. can be achieved,
outside this range depending on the dew point temperature 70 % r.H. to 90 % r.H.
Caution:
The on-site box must be absolutely airtight,
any existing pressure equalization must be sealed.
Recirculation Data:
Recirculation connection ∅ 125 mm
Recirculation volume min. 200m³/h
Installation location of the connections left side wall
Note:
The hose diameter has been reduced to ∅ 125 mm,
to allow the existing hoses to be reused.
Nominal voltage: 400V +6/-10 %,3/N, 50 Hz
Nominal power: 7.8 kW
Nominal current: 14.3 A
Compressor: TFH2480Z / TFH2511Z
Cooling unit: air-cooled
Refrigerant: R404A/R23
Weight: approx. 500 kg
The following points will be carried out in advance on our offered chambers:
1. Function check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are reserved!)
We are happy to answer any further questions by phone.

Technical characteristic Value
Item ID 24078
Condition Used
Model CTS CR-60/200
Manufacturer CTS
Weight 550000 g
document.querySelector("form > input[data-mail='subject']").value = "Webshop - Frage zu Artikel - Artikel-ID: " + vueApp.$store.state.items[24078].variation.documents[0].data.item.id;

EU Responsible Person

CTS Clima Temperatur Systeme GmbH
Lotzenäcker 21
72379 Hechingen Germany
info@cts-umweltsimulation.de
+49 7471 - 98 50 - 0

Manufacturer details

CTS
CTS Clima Temperatur Systeme GmbH
Germany

Switch to environmentally friendly refrigerant

The following work can be performed on climate chambers. Please contact us if you are interested.

 

  • Extraction and proper disposal of the previous refrigerant
  • Replacement of necessary components, if unavoidable
  • Evacuate the circuit and refill it with R 452A, for example.
  • Checking / adjusting overheating in expansion valves
  • Leak test
  • Test run of the system