CTS Climate Test Chamber CW-40/30 -40°C to +130°C Volume 30m³


Item ID: 24042

Condition: Used

Stock: Only ${ $store.getters['24042/currentItemVariation'].stock.net } in stock

The item is already sold

* Excl. VAT excl. Shipping

CTS


Type: CW-40/30
CTS Climate Chamber Climate Test Cell

Water-cooled
(converted to R-452a)
Footprint approx. (W x D x H): 2800 x 6830 x 2620
Test chamber approx. (W x D x H): 2500 x 5825 x 2300

Test chamber volume: 30 m³
Temperature tests:
Temperature range: -40°C to +130°C
Temperature deviation ± 1 K over time
Rate of temperature change on average
measured in the supply air without heat input
Heating: 1 K/min
Cooling: 1 K/min
from +95°C to -30°C
Climate tests:
Temperature range: +10°C to +95°C
Humidity range: 10% to +95% r.H
in the dew point range: +5°C to 89°C
Temperature deviation ± 0.5 K over time
Humidity deviation ±1- ±3% r.H over time
Nominal voltage: 400V +6/-10 % 3/N, PE, 50 Hz
Nominal power: 80.9 kW Nominal current: 126.6 A
Refrigerant: R-452a

Weight of test cell approx. 4079 kg
Weight of machine set: approx. 409 kg
Weight of control cabinet approx. 255 kg
Weight of condenser approx. 612 kg
Condition: used
Scope of delivery: (See image)
(Changes and errors in technical data are reserved!)
We would be happy to answer any further questions by phone.

Technical characteristic Value
Item ID 24042
Condition Used
Model CTS Klimaprüfzelle
Manufacturer CTS
Weight 6000000 g
document.querySelector("form > input[data-mail='subject']").value = "Webshop - Frage zu Artikel - Artikel-ID: " + vueApp.$store.state.items[24042].variation.documents[0].data.item.id;

EU Responsible Person

CTS Clima Temperatur Systeme GmbH
Lotzenäcker 21
72379 Hechingen Germany
info@cts-umweltsimulation.de
+49 7471 - 98 50 - 0

Manufacturer details

CTS
CTS Clima Temperatur Systeme GmbH
Germany

Switch to environmentally friendly refrigerant

The following work can be performed on climate chambers. Please contact us if you are interested.

 

  • Extraction and proper disposal of the previous refrigerant
  • Replacement of necessary components, if unavoidable
  • Evacuate the circuit and refill it with R 452A, for example.
  • Checking / adjusting overheating in expansion valves
  • Leak test
  • Test run of the system

Walk-in climate test cabinets