CTS Climate Test Chamber CS-70/300 Temperature -70 to 180°C 300 Liters 98358


Item ID: 20337

Condition: Used

Stock: Only ${ $store.getters['20337/currentItemVariation'].stock.net } in stock

The item is already sold

* Excl. VAT excl. Shipping

CTS


Here we offer you a climate testing chamber.
Technical specifications:
Temperature operating range
Temperature range in °C -70 / +180°C
Cooling rate 10 K/min
Heating rate 10 K/min
Temperature deviation, time-related in K ± 0.5 to ± 1 K
Humidity deviation, time-related ± 1 to ± 5 % r.H.
Climate tests
Temperature range: +10 °C to +90 °C
Humidity range: 10% to 98% relative humidity
Dimensions:
Test volume: 300 liters
Test chamber dimensions Height, approx. 600 mm, Width, approx. 850 mm, Depth, approx. 600 mm
External dimensions Height, approx. 2185 mm, Width, approx. 1050 mm, Depth, approx. 1850 mm
Operating data:
Electrical connection 400 V +6% -10%, 3/N, 50 Hz
Rated power 21.5 kW
Rated current 34.6 A
Refrigerant: R404A / R23
Weight: 900 Kg
Type: CS-70/300
For you as a buyer, the following information for your safety!
 
The following points will be carried out on our offered chambers in advance:
1. Function check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. After successful inspection, the chambers will undergo a test run monitored with calibrated devices.
Condition: used
Scope of delivery: (See pictures)
(Changes and errors in the technical data, specifications are subject to change!)
 
We would be happy to answer any further questions by phone.

Technical characteristic Value
Item ID 20337
Condition Used
Model CTS CS-70/300
Manufacturer CTS
Weight 800000 g
document.querySelector("form > input[data-mail='subject']").value = "Webshop - Frage zu Artikel - Artikel-ID: " + vueApp.$store.state.items[20337].variation.documents[0].data.item.id;

EU Responsible Person

CTS Clima Temperatur Systeme GmbH
Lotzenäcker 21
72379 Hechingen Germany
info@cts-umweltsimulation.de
+49 7471 - 98 50 - 0

Manufacturer details

CTS
CTS Clima Temperatur Systeme GmbH
Germany

Switch to environmentally friendly refrigerant

The following work can be performed on climate chambers. Please contact us if you are interested.

 

  • Extraction and proper disposal of the previous refrigerant
  • Replacement of necessary components, if unavoidable
  • Evacuate the circuit and refill it with R 452A, for example.
  • Checking / adjusting overheating in expansion valves
  • Leak test
  • Test run of the system