Binder climate chamber for constant conditions KBF 240 9120-0094


Item ID: 12666

Condition: Used

Stock: Only ${ $store.getters['12666/currentItemVariation'].stock.net } in stock

The item is already sold

* Excl. VAT excl. Shipping

Binder Constant Climate Chamber


Here we offer you a Binder Constant Climate Chamber.
Binder Constant Climate Chamber KBF 240
APT.line preheating technology with electronic control and cooling system ensures high temperature accuracy and reproducibility of results
Temperature range from -10°C to +100°C (without humidity control)
Humidity control range from 10% to 90% RH
Microprocessor MCS control with storage of 25 programs, 100 segments with a maximum of 500 program segments each
User-friendly LCD monitor
Real-time clock
Intuitive menu control
Integrated electronic recorder with continuous recording
Diverse options for graphical representation of process parameters
Microprocessor-controlled humidification and dehumidification system with capacitive humidity sensor
Internal glass door with seal
Temperature selection guard class 3.1 (DIN 12880) with optical and acoustic alarm
Environmentally friendly refrigerant R 134a
Cable gland with silicone plug Ø 30 mm, left side
Ensuring the fixed positioning of hoses including water supply and drainage (total length 6 m)
Ethernet interface for communication software APT-COM ™ DataControl System
2 pull-out stainless steel shelves
External dimensions: Width 1034 mm, Height 1370 mm, Depth 746 mm
Back wall distance 100 mm
Side wall distance 160 mm
Steam chamber volume 308 l
Height of water connections 84 ± 3 mm
Number of doors 2
Number of inner glass doors 2
Internal dimensions: Width 800 mm, Height 600 mm, Depth 500 mm
Internal volume 240 liters
Shelves (number standard / max.) 2/7
Load per shelf 30 kg
Total permissible load 70 kg
Weight (empty) 160 kg
Temperature properties
Temperature range without humidification / without lighting -10 °C ... + 100 °C
Temperature range with humidification / without lighting +10 °C ... +90 °C
Temperature fluctuations in the entire chamber without humidification at 10 °C ± 0.4 °C
Temperature fluctuations in the entire chamber without humidification at 37 °C ± 0.4 °C
Temperature fluctuations in the entire chamber with humidification ± 1 °C
Temperature fluctuation at 5 °C above room temperature ± 0.1 °C
Temperature fluctuations with cooling system running ± 0.5 °C
Heating time from room temperature to 37 °C 30 minutes
Cooling time from room temperature to 10 °C 35 minutes
Recovery time of temperature after opening the door for 30 sec. at 37 °C 5 minutes at 50 °C 4 minutes
Humidity fluctuation ± 1.5% relative humidity
Electrical properties:
Enclosure protection class according to EN 60529 IP 20
Nominal voltage (± 10%) 50/60 Hz 230 V
Nominal power 2.25 kW
Power consumption at 37 °C 550 W / hour
Type: KBF 240 / 9120-0094
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are reserved!)
 
We would be happy to answer any further questions by phone.

Technical characteristic Value
Item ID 12666
Condition Used
Model KBF 240
Manufacturer Binder
Weight 200000 g
document.querySelector("form > input[data-mail='subject']").value = "Webshop - Frage zu Artikel - Artikel-ID: " + vueApp.$store.state.items[12666].variation.documents[0].data.item.id;

EU Responsible Person

BINDER GmbH
Im Mittleren Ösch 5
78532 Tuttlingen Germany
CustomerSupport@binder-world.com
+49 7462/2005-0

Manufacturer details

Binder
BINDER GmbH
Germany

Switch to environmentally friendly refrigerant

The following work can be performed on climate chambers. Please contact us if you are interested.

 

  • Extraction and proper disposal of the previous refrigerant
  • Replacement of necessary components, if unavoidable
  • Evacuate the circuit and refill it with R 452A, for example.
  • Checking / adjusting overheating in expansion valves
  • Leak test
  • Test run of the system

Climate test cabinets