Autotherm cold water units, chiller (temperature control device) refurbished AKW 100 TK-TW6


Item ID: 24306

Condition: Used

Stock: Only ${ $store.getters['24306/currentItemVariation'].stock.net } in stock

The item is already sold

* Excl. VAT excl. Shipping

Autotherm


Type: Temperature Control Unit Autotherm AKW 100 TK-TW6
Temperature Control Unit Autotherm AKW 100 for Water / Glycol Temperature Control  (refurbished)
Autotherm cooling systems AKW: Powerful cooling and efficient removal of process heat.
Autotherm chillers, cooling units, and cooling systems ensure efficient and reliable
operation of your machines and processes by removing generated process heat and providing precise
temperature control. Liquid media such as water, coolant,
technical oils, or brines serve as heat carriers.
Areas of application:
Autotherm cooling systems are used in various industries and applications:
Automotive Industry
Metal Processing
Die Casting
Plastic Processing
Paper Production
Chemical Industry
Food Industry
Laser
Pharmaceutical Industry
Test Stands
Temperature Control Unit Autotherm AKW 100 TK-TW6
Temperature Range -47°C / +95°C
Heating Power 6.0 KW
Cooling Power at -40°C/ 1.0 KW
At 0°C / 6kW
Nominal Power 15.84 KW
Dimensions 1000mm x 1600 mm x 2000mm
Heating and Cooling
Refrigerant Quantity 4kg
Power Consumption: 400Volt/ 50 Hz
15900 Watts 27 A 4.2 bar
Weight approx. 1200 kg
Condition: used
Scope of delivery: (See image)
(Changes and errors in technical data are reserved!)
We would be happy to answer any further questions by phone.

Technical characteristic Value
Item ID 24306
Condition Used
Model Autotherm AKW100TK-TW6
Manufacturer Autotherm
Weight 1200000 g
document.querySelector("form > input[data-mail='subject']").value = "Webshop - Frage zu Artikel - Artikel-ID: " + vueApp.$store.state.items[24306].variation.documents[0].data.item.id;

EU Responsible Person

autotherm Nenninger GmbH & Co. KG
Wichernstraße 13
97631 Bad Königshofen Germany
info@autotherm.net
+49 9761 9140-0

Manufacturer details

Autotherm
Germany

Switch to environmentally friendly refrigerant

The following work can be performed on climate chambers. Please contact us if you are interested.

 

  • Extraction and proper disposal of the previous refrigerant
  • Replacement of necessary components, if unavoidable
  • Evacuate the circuit and refill it with R 452A, for example.
  • Checking / adjusting overheating in expansion valves
  • Leak test
  • Test run of the system

Climate test cabinets