Angelantoni / ACS Climate Chamber with Humidity -40°C to + 180°C 600 Liters CH600
Item ID: 22415
Condition: Used
Stock: Only ${ $store.getters['22415/currentItemVariation'].stock.net } in stock
PAYMENT METHODS:
²
* Excl. VAT excl. Shipping
Angelantoni / ACS Climate Chamber
Here we offer you an Angelantoni / ACS climate chamber.
Angelantoni / ACS climate chamber with humid air cooling
Test chamber volume 567 liters
External dimensions: Width 1100 mm x Depth 1705 mm x Height 1910 mm
Internal dimensions: Width 850 mm x Depth 746 mm x Height 895 mm
Key values for temperature tests
Temperature range -40°C to +180°C
Maximum temperature change rate from -40°C to +180°C 3.2 K/min
Maximum temperature change rate from +180°C to -40°C 2.5 K/min
Heat compensation
at -25°C. 1000 W
Key values for climate tests
Temperature range: +10°C to +95°C
Humidity range: 10% to 98% r.H.
Accuracy 0.25 ÷ 0.3
Nominal voltage: 400V +6/-10% 50Hz 3+N+T
Nominal power: 11 kW Nominal current: 20 A
Fuse on site: 12.1 A slow-blow
Refrigerant: R404 A
Weight: approx. 820 kg
Type: CH600
For you as a buyer, the following information for your safety!
The following points will be carried out on our offered chambers in advance:
1. Function check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will undergo a test run monitored with calibrated devices.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data, specifications are reserved!)
Further questions can be answered by phone.
Switch to environmentally friendly refrigerant
The following work can be performed on climate chambers. Please contact us if you are interested.
- Extraction and proper disposal of the previous refrigerant
- Replacement of necessary components, if unavoidable
- Evacuate the circuit and refill it with R 452A, for example.
- Checking / adjusting overheating in expansion valves
- Leak test
- Test run of the system