ThermoFisher / Dionex UltiMate 3000 System (FLM-3100, VWD-3400RS, WPS-3000TPL RS, SDR-3600, DGP-3600M)


Item ID: 24837

Condition: Used

Stock: Only ${ $store.getters['24837/currentItemVariation'].stock.net } in stock

EUR 10,000.00 *
Content 1 piece
Unit price EUR 10,000.00 / piece
The item is in stock

PAYMENT METHODS:

²


* Excl. VAT excl. Shipping

Dionex / ThermoFisher


 

FLM:
Temperature range: 5–70 °C (max. 15 °C below ambient temperature)
Temperature accuracy: ±0.5 °C
Temperature stability: ±0.1 °C
Temperature precision: ±0.1 °C
Column capacity: Up to 3 columns, max. 30 cm length
Heating time: From 20 to 50 °C in less than 25 min
(at 23 °C ambient temperature, ±0.5 °C)
Cooling time: From 50 to 20 °C in less than 35 min
(at 23 °C ambient temperature, ±0.5 °C)
Control: All functions software-controlled via USB 1.1
I/O interfaces: 2 digital inputs, 2 programmable relay outputs
Column recognition: Electronic identification system for 3 columns
Switching valves: 1 or 2 thermostatically controlled micro valves with low dispersion
(10 connections or 6 connections)
Flow distributor: Nano, capillary, or thermostatically controlled micro flow distributor with
flow distributor identification system
Flow control: Electronically controlled and actively balanced flow divider,
independent of solvent composition and back pressure
Column flow range: 50 nL/min to 2.5 mL/min using a predefined divider and
active flow control
Flow range selection: 50 nL/min to 1000 nL/min (using a nano-LC splitter)
0.5 μL/min to 10 μL/min (with a capillary LC splitter)
10 μL/min to 160 μL/min (with a micro LC splitter)
Gradient delay time: Typically < 1.5 min at 200 nL/min to the splitter output
Max. column pressure: 35 MPa (4900 psi)
Wetted parts: Quartz glass, stainless steel (1.4571, 316L), PEEK;
Drain line: PTFE, aluminum oxide (Al 2 O3)
Safety features: Humidity sensor, gas sensor, and leakage sensor for the flow control valve
VWD
Optical design: Dual-beam photometer (monochromator)
Multi-wavelength UV/VIS detector
Light source: VWD-3400RS: Deuterium lamp and tungsten lamp
Temperature control for both lamps
Wavelength range: 190 to 900 nm
Tungsten lamp recommended for wavelengths > 600 nm.
Noise:
At one wavelength: <± 2.0 μAU (typical):
dry analytical flow cell, wavelength: 230 nm, time constant:
2 seconds, only deuterium lamp switched on
<± 3.5 μAU (typical: <± 2.5 μAU):
dry analytical flow cell, wavelength: 254 nm, time constant
(according to ASTM): 1 second, only deuterium lamp switched on
<± 5 μAU (typical):
dry analytical flow cell, wavelength: 520 nm, time constant
(according to ASTM): 1 second, only tungsten lamp switched on
All values were achieved within a warm-up time of 60 minutes (typical)
With a flowing analytical flow cell, comparable
values can be achieved. A prerequisite is a high-quality eluent
without impurities and dissolved gas, with constant temperature and
constant refractive index.
At multiple wavelengths
(VWD-3400RS):
<± 10 μAU (typical: <± 7 μAU):
dry analytical flow cell, wavelength: 254 nm and 280 nm,
time constant: 2 seconds, data rate: 2 Hz, only deuterium lamp
switched on
<± 10 μAU (typical: <± 7 μAU):
dry analytical flow cell, wavelength: 450 nm and 520 nm,
time constant: 2 seconds, data rate: 2 Hz, only tungsten lamp
switched on
All values were achieved within a warm-up time of 60 minutes (typical)
With a flowing analytical flow cell, comparable
values can be achieved. A prerequisite is a high-quality eluent
without impurities and dissolved gas, with constant temperature and
constant refractive index
WPS-3000TPL (RS)

Sample temperature control 4 to 45 °C, max. 22 °C below ambient temperature
Sample temperature accuracy
±2 °C at a setpoint of 10 °C at ambient temperatures of ≤25 °C and ≤50 %
relative humidity
Control All functions software-controlled via USB 1.1
Integrated USB 1.1 hub with 3 free USB ports
I/O interfaces 4 digital inputs, 4 programmable relay outputs
User input/display LCD display of system parameters
Standby button
3 LEDs for status monitoring (power supply, connection, status)
4 softkeys for operation during initial installation and maintenance
Safety features Leakage sensor, automatic plate/vial detection, needle overload protection
(puncturing device), internal monitoring of all mechanical processes,
autosampler with sample temperature control: Monitoring of function and
cooling performance by 3 temperature sensors
GLP functions In Chromeleon:
Full support for automatic device qualification (AutoQ TM) and
wellness monitoring
All system parameters are recorded in the Chromeleon audit trail
 
 
Condition: used / gebraucht
Scope of delivery: (See images, accessories and documentation as shown)
(Changes and errors in technical data, specifications are subject to change!)
We would be happy to answer any further questions by phone.

Technical characteristic Value
Item ID 24837
Condition Used
Model ThermoFisher / Dionex UltiMate 3000 System
Manufacturer Thermo Fisher Scientific
Content 1 piece
Weight 200000 g
document.querySelector("form > input[data-mail='subject']").value = "Webshop - Frage zu Artikel - Artikel-ID: " + vueApp.$store.state.items[24837].variation.documents[0].data.item.id;

EU Responsible Person

Thermo Fisher Scientific Germany B.V. & Co. KG
Ludwigstr. 5b
38106 Braunschweig Germany
info.germany@thermofisher.com
+49 721 / 40940

Manufacturer details

Thermo Fisher Scientific
USA