ThermoFisher / Dionex UltiMate 3000 System (FLM-3100, VWD-3400RS, WPS-3000TPL RS, SDR-3600, DGP-3600M)
Item ID: 24837
Condition: Used
Stock: Only ${ $store.getters['24837/currentItemVariation'].stock.net } in stock
EUR 10,000.00
*
Content
1 piece
Unit price
EUR 10,000.00 / piece
The item is in stock
PAYMENT METHODS:
²

* Excl. VAT excl. Shipping
Dionex / ThermoFisher
FLM:
Temperature range: 5–70 °C (max. 15 °C below ambient temperature)
Temperature accuracy: ±0.5 °C
Temperature stability: ±0.1 °C
Temperature precision: ±0.1 °C
Column capacity: Up to 3 columns, max. 30 cm length
Heating time: From 20 to 50 °C in less than 25 min
(at 23 °C ambient temperature, ±0.5 °C)
Cooling time: From 50 to 20 °C in less than 35 min
(at 23 °C ambient temperature, ±0.5 °C)
Control: All functions software-controlled via USB 1.1
I/O interfaces: 2 digital inputs, 2 programmable relay outputs
Column recognition: Electronic identification system for 3 columns
Switching valves: 1 or 2 thermostatically controlled micro valves with low dispersion
(10 connections or 6 connections)
Flow distributor: Nano, capillary, or thermostatically controlled micro flow distributor with
flow distributor identification system
Flow control: Electronically controlled and actively balanced flow divider,
independent of solvent composition and back pressure
Column flow range: 50 nL/min to 2.5 mL/min using a predefined divider and
active flow control
Flow range selection: 50 nL/min to 1000 nL/min (using a nano-LC splitter)
0.5 μL/min to 10 μL/min (with a capillary LC splitter)
10 μL/min to 160 μL/min (with a micro LC splitter)
Gradient delay time: Typically < 1.5 min at 200 nL/min to the splitter output
Max. column pressure: 35 MPa (4900 psi)
Wetted parts: Quartz glass, stainless steel (1.4571, 316L), PEEK;
Drain line: PTFE, aluminum oxide (Al 2 O3)
Safety features: Humidity sensor, gas sensor, and leakage sensor for the flow control valve
VWD
Optical design: Dual-beam photometer (monochromator)
Multi-wavelength UV/VIS detector
Light source: VWD-3400RS: Deuterium lamp and tungsten lamp
Temperature control for both lamps
Wavelength range: 190 to 900 nm
Tungsten lamp recommended for wavelengths > 600 nm.
Noise:
At one wavelength: <± 2.0 μAU (typical):
dry analytical flow cell, wavelength: 230 nm, time constant:
2 seconds, only deuterium lamp switched on
<± 3.5 μAU (typical: <± 2.5 μAU):
dry analytical flow cell, wavelength: 254 nm, time constant
(according to ASTM): 1 second, only deuterium lamp switched on
<± 5 μAU (typical):
dry analytical flow cell, wavelength: 520 nm, time constant
(according to ASTM): 1 second, only tungsten lamp switched on
All values were achieved within a warm-up time of 60 minutes (typical)
With a flowing analytical flow cell, comparable
values can be achieved. A prerequisite is a high-quality eluent
without impurities and dissolved gas, with constant temperature and
constant refractive index.
At multiple wavelengths
(VWD-3400RS):
<± 10 μAU (typical: <± 7 μAU):
dry analytical flow cell, wavelength: 254 nm and 280 nm,
time constant: 2 seconds, data rate: 2 Hz, only deuterium lamp
switched on
<± 10 μAU (typical: <± 7 μAU):
dry analytical flow cell, wavelength: 450 nm and 520 nm,
time constant: 2 seconds, data rate: 2 Hz, only tungsten lamp
switched on
All values were achieved within a warm-up time of 60 minutes (typical)
With a flowing analytical flow cell, comparable
values can be achieved. A prerequisite is a high-quality eluent
without impurities and dissolved gas, with constant temperature and
constant refractive index
WPS-3000TPL (RS)
Sample temperature control 4 to 45 °C, max. 22 °C below ambient temperature
Sample temperature accuracy
±2 °C at a setpoint of 10 °C at ambient temperatures of ≤25 °C and ≤50 %
relative humidity
Control All functions software-controlled via USB 1.1
Integrated USB 1.1 hub with 3 free USB ports
I/O interfaces 4 digital inputs, 4 programmable relay outputs
User input/display LCD display of system parameters
Standby button
3 LEDs for status monitoring (power supply, connection, status)
4 softkeys for operation during initial installation and maintenance
Safety features Leakage sensor, automatic plate/vial detection, needle overload protection
(puncturing device), internal monitoring of all mechanical processes,
autosampler with sample temperature control: Monitoring of function and
cooling performance by 3 temperature sensors
GLP functions In Chromeleon:
Full support for automatic device qualification (AutoQ TM) and
wellness monitoring
All system parameters are recorded in the Chromeleon audit trail
Condition: used / gebraucht
Scope of delivery: (See images, accessories and documentation as shown)
(Changes and errors in technical data, specifications are subject to change!)
We would be happy to answer any further questions by phone.
| Technical characteristic | Value |
|---|---|
| Item ID | 24837 |
| Condition | Used |
| Model | ThermoFisher / Dionex UltiMate 3000 System |
| Manufacturer | Thermo Fisher Scientific |
| Content | 1 piece |
| Weight | 200000 g |
EU Responsible Person
Thermo Fisher Scientific Germany B.V. & Co. KG
Ludwigstr. 5b
38106 Braunschweig
Germany
info.germany@thermofisher.com
+49 721 / 40940
Manufacturer details
Thermo Fisher Scientific
USA
