Micro Motion F025S mass flow meter / Coriolis / 1700 transmitter / 100 bar
Item ID: 25493
Condition: Used
Stock: Only ${ $store.getters['25493/currentItemVariation'].stock.net } in stock
EUR 700.00
*
Content
1 piece
Unit price
€700.00 / piece
The item is in stock
PAYMENT METHODS:
²

if(!document.getElementById('paypal-smart-payment-script'))
{
var script = document.createElement("script");
script.type = "module";
script.id = "paypal-smart-payment-script";
script.src = "https://cdn02.plentyone.com/7ukspn3affoc/plugin/23/paypal/js/smartPaymentScript.min.js";
script.setAttribute("data-client-id", "AfslQana4f4CQjHvRBnUc6vBJg5jgJuZFwM-SbrTiGKUAqB7MrxQv3QWFdQ6U1h7ogMDokT1DNBzRxMw");
script.setAttribute("data-user-id-token", "");
script.setAttribute("data-merchant-id", "HAR2LLRJHKH66");
script.setAttribute("data-currency", "EUR");
script.setAttribute("data-append-trailing-slash", "");
script.setAttribute("data-locale", "en_GB");
script.setAttribute("sandbox", "");
script.setAttribute("googlePayComponent", 0);
script.setAttribute("applePayComponent", 0);
script.setAttribute("logToken", "4157bbeeecb11ef779cbbcf70c324159");
document.body.appendChild(script);
} else {
var script = document.getElementById('paypal-smart-payment-script');
script.src = "https://cdn02.plentyone.com/7ukspn3affoc/plugin/23/paypal/js/smartPaymentScript.min.js";
script.setAttribute("data-client-id", "AfslQana4f4CQjHvRBnUc6vBJg5jgJuZFwM-SbrTiGKUAqB7MrxQv3QWFdQ6U1h7ogMDokT1DNBzRxMw");
script.setAttribute("data-user-id-token", "");
script.setAttribute("data-merchant-id", "HAR2LLRJHKH66");
script.setAttribute("data-currency", "EUR");
script.setAttribute("data-append-trailing-slash", "");
script.setAttribute("data-locale", "en_GB");
script.setAttribute("sandbox", "");
script.setAttribute("googlePayComponent", 0);
script.setAttribute("applePayComponent", 0);
script.setAttribute("logToken", "4157bbeeecb11ef779cbbcf70c324159");
}
if (typeof paypal_plenty_sdk === 'undefined' || typeof renderPayPalButtons !== 'function') {
document.addEventListener('payPalScriptInitialized', () => {
renderPayPalButtons('6b0205674c226', 'paypal', 'buynow', 'rect', 'gold');
});
} else {
renderPayPalButtons('6b0205674c226', 'paypal', 'buynow', 'rect', 'gold');
}
if(!document.getElementById('paypal-smart-payment-script'))
{
var script = document.createElement("script");
script.type = "module";
script.id = "paypal-smart-payment-script";
script.src = "https://cdn02.plentyone.com/7ukspn3affoc/plugin/23/paypal/js/smartPaymentScript.min.js";
script.setAttribute("data-client-id", "AfslQana4f4CQjHvRBnUc6vBJg5jgJuZFwM-SbrTiGKUAqB7MrxQv3QWFdQ6U1h7ogMDokT1DNBzRxMw");
script.setAttribute("data-user-id-token", "");
script.setAttribute("data-merchant-id", "HAR2LLRJHKH66");
script.setAttribute("data-currency", "EUR");
script.setAttribute("data-append-trailing-slash", "");
script.setAttribute("data-locale", "en_GB");
script.setAttribute("sandbox", "");
script.setAttribute("googlePayComponent", 0);
script.setAttribute("applePayComponent", 0);
script.setAttribute("logToken", "4157bbeeecb11ef779cbbcf70c324159");
document.body.appendChild(script);
} else {
var script = document.getElementById('paypal-smart-payment-script');
script.src = "https://cdn02.plentyone.com/7ukspn3affoc/plugin/23/paypal/js/smartPaymentScript.min.js";
script.setAttribute("data-client-id", "AfslQana4f4CQjHvRBnUc6vBJg5jgJuZFwM-SbrTiGKUAqB7MrxQv3QWFdQ6U1h7ogMDokT1DNBzRxMw");
script.setAttribute("data-user-id-token", "");
script.setAttribute("data-merchant-id", "HAR2LLRJHKH66");
script.setAttribute("data-currency", "EUR");
script.setAttribute("data-append-trailing-slash", "");
script.setAttribute("data-locale", "en_GB");
script.setAttribute("sandbox", "");
script.setAttribute("googlePayComponent", 0);
script.setAttribute("applePayComponent", 0);
script.setAttribute("logToken", "4157bbeeecb11ef779cbbcf70c324159");
}
* Excl. VAT excl. Shipping
MICRO MOTION
Coriolis Mass Flow Meter / F-Series / 100 bar / ATEX
Micro Motion F025S
Coriolis mass flow meter with Micro Motion 1700 transmitter for precise
measurement of mass flow, density, and process temperature
For sale is a Micro Motion Coriolis mass flow measurement system
of the F-Series, consisting of an F025S mass flow sensor
and a Micro Motion 1700 transmitter with digital display.
The measurement system operates based on the Coriolis measurement principle
and is used for the direct determination of mass flow of liquids and gases.
Additionally, density and temperature can be measured, among other parameters.
The Micro Motion F-Series is designed for precise flow measurements
in industrial process and test stand applications.
Technical Data:
Manufacturer: Micro Motion, Inc. / Emerson
Model Sensor: F025S319CCAZ6ZZZZ
Sensor S/N: 760145
Series: F-Series
Product Type: Coriolis mass flow meter / Mass Flow Sensor
Year of Manufacture: 2006
Manufacturing Location Sensor: Mexico
Measurement Principle: Coriolis
Measured Values: Mass flow / Density / Temperature
Max. Operating Pressure: 100 bar at 25 °C
Sensor Material: 316L Stainless Steel
Flow Cal: 26.9464.65
Dens Cal: 06273065994.34
K1: 6278.253
K2: 6598.667
TC: 4.34
Sensor Electronics:
Input: 17.3 V / 160 mA
Temperature Code: T1–T5
Ambient Temperature: -40 °C to +55 °C
Explosion Protection: ATEX / Ex version
Labeling according to nameplate: EEx ib IIC T1–T5 / II 2G
Transmitter:
Manufacturer: Micro Motion
Model / Type: 1700111DFZ6ZZZ
S/N: 3744378
Assigned Sensor S/N: 760145
Product Type: Micro Motion 1700 Transmitter
Display: Digital LCD
Operation: Scroll / Select
Housing: Field housing / Ex version
Protection Class according to nameplate: IP66
Ambient Temperature: -40 °C to +55 °C
Power Consumption: 7 W
Application Areas:
Industrial flow measurement
Process measurement technology
Dosing and filling systems
Chemical and process engineering plants
Test stand technology
Liquid and gas measurement
Scope of Delivery:
1 × Micro Motion F025S Coriolis mass flow meter
with integrated Micro Motion 1700 transmitter,
including connections and cables as shown
Condition:
Used condition
With age- and usage-related signs of wear
see pictures.
A current calibration or measurement verification has not been performed by us.
Shipping via UPS possible.
Changes, errors, and prior sale reserved.
Further questions can be answered by phone.
| Technical characteristic | Value |
|---|---|
| Item ID | 25493 |
| Condition | Used |
| Model | Micro Motion F025S Massedurchflussmesser / Coriolis / 1700 Transmitter / |
| Manufacturer | Micro Motion |
| Content | 1 piece |
| Weight | 8000 g |
EU Responsible Person
Emerson
Katzbergstr. 1
40764 Langenfeld
Germany
Anfrage.De@Emerson.com
+49 2173 33480
Manufacturer details
Micro Motion
Emerson Electric Co.
USA