EA Elektro-Automatik Laboratory Power Supply EA-EL 9080-170 B


Item ID: 24358

Condition: Used

Stock: Only ${ $store.getters['24358/currentItemVariation'].stock.net } in stock

EUR 3,300.00 *
Content 1 piece
Unit price EUR 3,300.00 / piece
The item is in stock

PAYMENT METHODS:

²


* Excl. VAT excl. Shipping

EA Elektro Automatik


Type: EA-EL 9080-170 B

Electronic DC Load, USB / Analog / Master-Slave, Programmable, 80V, 170A, 2.4kW
Technical Data:
Mains Voltage 90...264 V AC
Mains Connection Type Socket
Mains Frequency 45...65 Hz
Mains Fuse T 6.3
Power Consumption Max. 90 W
Leakage Current < 3.5 mA
DC Input
Input Voltage 80 V
Input Power 2400 W
Input Current 170 A
Overvoltage Protection Range 0...1.03 * UNom
Overcurrent Protection Range 0...1.1 * INom
Overpower Protection Range 0...1.1 * PMax
Max. Permissible Input Voltage 88 V
Min. Input Voltage for IMax Approx. 2.2 V
Temperature Coefficient of Set Values Δ / K Current / Voltage: 30 ppm
Voltage Regulation
Adjustment Range 0...81.6 V
Stability at ΔI < 0.05%
Accuracy (at 23 ± 5°C) ≤ 0.1% UNom
Display: Accuracy ≤ 0.1% UNom
Compensation Remote Sensing Max. 5% UNom
Current Regulation
Adjustment Range 0...173.4 A
Stability at ΔU < 0.1% INom
Accuracy (at 23 ± 5°C) ≤ 0.2% INom
Display: Accuracy ≤0.1% INom
Rise Time 10...90% INom < 23 μs
Fall Time 90...10% INom < 46 μs
Power Regulation
Adjustment Range 0…2428 W
Accuracy (at 23 ± 5°C) < 0.5% PMax
Display: Accuracy ≤ 0.2% PMax
Resistance Regulation
Adjustment Range 0.04…15.3 Ω
Accuracy (at 23 ± 5°C) ≤1% of Resistance End Value + 0.3% of INom
Display: Accuracy Included in the Accuracy of the Set Value
EL 9080-170 B:
Analog Interface:
Set Value Inputs U, I, P, R
Actual Value Outputs U, I
Control Signals DC on/off, Remote Control on/off, R-Mode on/off
Signal Messages CV, OVP, OCP, OPP, OT, PF, DC on/off
Galvanic Isolation to Device Max. 400 V DC
Sampling Rate Set Value Inputs 500 Hz
Isolation:
Input (DC) to Housing DC-Minus: permanently max. ±400 V
DC-Plus: permanently max. ±400 V + max. Input Voltage
Input (AC) to Input (DC) Max. 2500 V, short-term
Climate:
Cooling Type Temperature Controlled Fans
Ambient Temperature 0...50 °C
Storage Temperature -20...70 °C
Digital Interfaces
Built-in 1x USB-B for Communication, 1x USB-A for Functions, 1x Master-Slave Bus
Slot for Digital Modules Optional: CAN, CANopen, Profibus, Profinet, RS232, Ethernet, ModBus TCP, Ether-
CAT
Galvanic Isolation to Device Max. 400 V DC
Connections:
Rear Share-Bus, DC Input, AC Input, Sense, Analog Interface, USB-B, Master-
Slave Bus, Interface Module Slot
Front USB-A
Dimensions:
Housing (WxHxD) 19“ x 2 HE x 464 mm
Total (WxHxD) 483 mm x 88 mm x 538 mm
Standards EN 61010-1:2007-11, EN 61000-6-2:2005, EN 61000-6-3:2006 Class B
Weight ≈ 11 kg
Documents & Downloads
Data Sheet: User Manual
Condition: used
Scope of Delivery: (See Image)
(Changes and errors in the technical data are reserved!)
We would be happy to answer any further questions by phone.

Technical characteristic Value
Item ID 24358
Condition Used
Model Labornetzteil EA-EL 9080
Manufacturer EA
Content 1 piece
Weight 32000 g
document.querySelector("form > input[data-mail='subject']").value = "Webshop - Frage zu Artikel - Artikel-ID: " + vueApp.$store.state.items[24358].variation.documents[0].data.item.id;

EU Responsible Person

EA Elektro-Automatik GmbH
Helmholtzstr. 31-37
41747 Viersen Germany
ea1974@elektroautomatik.com
+49 2162 3785 0

Manufacturer details

EA
EA Elektro-Automatik GmbH
Germany